LAPSE:2023.10456
Published Article
LAPSE:2023.10456
Water Wall Tubes’ High Temperature Corrosion Root Cause Investigation: A 300 MW Level Boiler Case
Xiaohe Xiong, Falin Chen, Liangyu Li, Houzhang Tan
February 27, 2023
Abstract
High temperature corrosion poses a great threat to boiler water wall safe operation. To investigate the corrosion root cause, a 300 MW level boiler water wall high temperature H2S corrosion case was reported. The typical hydrogen sulfide H2S corrosion feature was large amounts of sulfur which could be found in the cut down sample tube corrosion layer, with a thickness of 482 μm. In addition, huge amounts of lead (Pb) could be found in the corrosion layer, which resulted from the lead sulfide (PbS) deposition when the high temperature flue gas condensed at the water wall tubes. Meanwhile, the sulfur in the corrosion layer was closely related to the H2S concentration in the water wall ambience. The related ambience test showed that the H2S could achieve up to 1000 ppm when the boiler was in operation, far larger than the suggested reference value of 100 ppm. Hence, the overlarge H2S concentration was a vital factor for the tube corrosion. To further investigate the reason why the H2S was kept in such high concentration in the boiler long term operation, and the reasons for the over-high sulfur content in the coal and the over-large diameter of the imaginary circle of primary air (DICPA), two factors were obtained. The peak sulfur content reached 2.5% and the suggested sulfur content was below 1%. The DICPA was so large (1580 mm) that the pulverized coal easily scoured the water wall tubes, which would boost the thinning process of the tubes. To relieve the high temperature corrosion, improve the coal qualities, decrease the DICPA, adjust the operation diameter and adopt a coating technology four measures were suggested.
Keywords
boiler, H2S, high temperature corrosion, reducing ambience
Suggested Citation
Xiong X, Chen F, Li L, Tan H. Water Wall Tubes’ High Temperature Corrosion Root Cause Investigation: A 300 MW Level Boiler Case. (2023). LAPSE:2023.10456
Author Affiliations
Xiong X: MOE Key Laboratory of Thermo-Fluid Science and Engineering, Xi’an Jiaotong University, Xi’an 710049, China
Chen F: MOE Key Laboratory of Thermo-Fluid Science and Engineering, Xi’an Jiaotong University, Xi’an 710049, China
Li L: MOE Key Laboratory of Thermo-Fluid Science and Engineering, Xi’an Jiaotong University, Xi’an 710049, China
Tan H: MOE Key Laboratory of Thermo-Fluid Science and Engineering, Xi’an Jiaotong University, Xi’an 710049, China
Journal Name
Energies
Volume
16
Issue
4
First Page
1767
Year
2023
Publication Date
2023-02-10
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en16041767, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.10456
This Record
External Link

https://doi.org/10.3390/en16041767
Publisher Version
Download
Files
Feb 27, 2023
Main Article
License
CC BY 4.0
Meta
Record Statistics
Record Views
299
Version History
[v1] (Original Submission)
Feb 27, 2023
 
Verified by curator on
Feb 27, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.10456
 
Record Owner
Auto Uploader for LAPSE
Links to Related Works
Directly Related to This Work
Publisher Version