LAPSE:2023.10056
Published Article

LAPSE:2023.10056
Second Harmonic Current Reduction Control for Two-Stage Inverter with a New Inductor Current Feedback Path
February 27, 2023
Abstract
The instantaneous output power of the two-stage inverter pulsates at twice the output frequency, resulting in the second harmonic current (SHC) in the front-end dc-dc converter. To reduce the SHC in the inductance branch while maintaining good dynamic performance, this paper proposes a control scheme based on a new inductor current feedback path in the front-end buck converter. In the scheme, through the equivalent gain, the virtual resistor, and the bandpass filter, the inductor current is fed to the front of the voltage regulator. The feedback function simplification is studied and the implementation of the proposed scheme is illustrated. With considerations of both reducing the SHC and improving the dynamic performance, the parameter design approach for the feedback function is also presented for the proposed SHC reduction control scheme, and the performance analysis and comparison from the viewpoint of output impedance are provided. The simulation model and the prototype of a 10 kW two-stage inverter are constructed. The simulation and experimental results about the low SHC in the front-end buck converter and the fast dynamic response during the load transient verify the effectiveness of the proposed scheme.
The instantaneous output power of the two-stage inverter pulsates at twice the output frequency, resulting in the second harmonic current (SHC) in the front-end dc-dc converter. To reduce the SHC in the inductance branch while maintaining good dynamic performance, this paper proposes a control scheme based on a new inductor current feedback path in the front-end buck converter. In the scheme, through the equivalent gain, the virtual resistor, and the bandpass filter, the inductor current is fed to the front of the voltage regulator. The feedback function simplification is studied and the implementation of the proposed scheme is illustrated. With considerations of both reducing the SHC and improving the dynamic performance, the parameter design approach for the feedback function is also presented for the proposed SHC reduction control scheme, and the performance analysis and comparison from the viewpoint of output impedance are provided. The simulation model and the prototype of a 10 kW two-stage inverter are constructed. The simulation and experimental results about the low SHC in the front-end buck converter and the fast dynamic response during the load transient verify the effectiveness of the proposed scheme.
Record ID
Keywords
bandpass filter, inductor current feedback, second harmonic current (SHC), two-stage inverter, virtual resistor
Subject
Suggested Citation
Dong H, Xu J. Second Harmonic Current Reduction Control for Two-Stage Inverter with a New Inductor Current Feedback Path. (2023). LAPSE:2023.10056
Author Affiliations
Dong H: Faculty of Information Technology, Beijing University of Technology, Beijing 100124, China
Xu J: Faculty of Information Technology, Beijing University of Technology, Beijing 100124, China
Xu J: Faculty of Information Technology, Beijing University of Technology, Beijing 100124, China
Journal Name
Energies
Volume
15
Issue
17
First Page
6280
Year
2022
Publication Date
2022-08-28
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en15176280, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.10056
This Record
External Link

https://doi.org/10.3390/en15176280
Publisher Version
Download
Meta
Record Statistics
Record Views
189
Version History
[v1] (Original Submission)
Feb 27, 2023
Verified by curator on
Feb 27, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.10056
Record Owner
Auto Uploader for LAPSE
Links to Related Works
[0.22 s]