LAPSE:2019.1482
Published Article
LAPSE:2019.1482
A 3-D Coupled Magneto-Fluid-Thermal Analysis of a 220 kV Three-Phase Three-Limb Transformer under DC Bias
Ruohan Gong, Jiangjun Ruan, Jingzhou Chen, Yu Quan, Jian Wang, Shuo Jin
December 10, 2019
Abstract
This paper takes a typical 220 kV three-phase three-limb oil-immersed transformer as an example, this paper building transient field-circuit coupled model and 3D coupled magneto -fluid-thermal model. Considering a nonlinear B⁻H curve, the magneto model uses the field-circuit coupled finite element method (FEM) to calculate the magnetic flux distribution of the core and the current distribution of the windings when the transformer is at a rated current and under direct current (DC) bias. Taking the electric power losses of the core and windings as a heat source, the temperature inside the transformer and the velocity of the transformer oil are analyzed by the finite volume method (FVM) in a fluid-thermal field. In order to improve the accuracy of the calculation results, the influence of temperature on the electrical resistivity of the windings and the physical parameter of the transformer oil are taken into account in the paper. Meanwhile, the convective heat transfer coefficient of the FVM model boundary is determined by its temperature. By iterative computations, the model is updated according to the thermal field calculation result until the maximum difference in hot spot temperature between the two adjacent steps is less than 0.01 K. The result calculated by the coupling method agrees well with the empirical equation result according to IEC 60076-7.
Keywords
DC bias, field-circuit coupled analysis, magneto-fluid-thermal coupled analysis, temperature rise, three-phase three-limb transformer
Suggested Citation
Gong R, Ruan J, Chen J, Quan Y, Wang J, Jin S. A 3-D Coupled Magneto-Fluid-Thermal Analysis of a 220 kV Three-Phase Three-Limb Transformer under DC Bias. (2019). LAPSE:2019.1482
Author Affiliations
Gong R: School of Electrical Engineering, Wuhan University, No. 8, South Road of Eastern Lake, Wuhan 430072, China
Ruan J: School of Electrical Engineering, Wuhan University, No. 8, South Road of Eastern Lake, Wuhan 430072, China
Chen J: School of Electrical Engineering, Wuhan University, No. 8, South Road of Eastern Lake, Wuhan 430072, China
Quan Y: School of Electrical Engineering, Wuhan University, No. 8, South Road of Eastern Lake, Wuhan 430072, China
Wang J: School of Electrical Engineering, Wuhan University, No. 8, South Road of Eastern Lake, Wuhan 430072, China
Jin S: School of Electrical Engineering, Wuhan University, No. 8, South Road of Eastern Lake, Wuhan 430072, China
[Login] to see author email addresses.
Journal Name
Energies
Volume
10
Issue
4
Article Number
E422
Year
2017
Publication Date
2017-03-23
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en10040422, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2019.1482
This Record
External Link

https://doi.org/10.3390/en10040422
Publisher Version
Download
Files
Dec 10, 2019
Main Article
License
CC BY 4.0
Meta
Record Statistics
Record Views
734
Version History
[v1] (Original Submission)
Dec 10, 2019
 
Verified by curator on
Dec 10, 2019
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2019.1482
 
Record Owner
Calvin Tsay
Links to Related Works
Directly Related to This Work
Publisher Version
(0.31 seconds) 0 + 0.02 + 0.15 + 0.05 + 0 + 0.02 + 0.01 + 0 + 0.01 + 0.02 + 0 + 0