LAPSE:2018.0913v1
Published Article

LAPSE:2018.0913v1
A New Robust Decoupled Control of the Stator Active and Reactive Currents for Grid-Connected Doubly-Fed Induction Generators
November 27, 2018
Abstract
This paper addresses the grid-connected variable speed doubly-fed induction generator, and proposes a new decoupled control to replace the conventional decoupled active and reactive powers (P-Q) control. The proposed decoupled control is based on decoupling the stator active and reactive currents, in contrast with the conventional decoupled P-Q control, which is based on decoupling the stator active and reactive powers by forcing the stator d- or q-voltage to zero. The proposed decoupled control has all the advantages of the conventional decoupled P-Q control such as constant switching frequency and robustness against slip angle inaccuracy, and it has some additional advantages: The proposed control requires less machine parameters; for the controller design, it requires the stator-to-rotor turns ratio only; for the online calculation, it does not requires any machine parameter. The proposed decoupled control is more flexible and robust since the control is independent of the grid voltage orientation. It is robust against variation in the grid voltage amplitude. Several experiments are carried out using a 1.1 kW doubly-fed induction generator (DFIG), and the results support the proposed decoupled control and demonstrate some of its advantages.
This paper addresses the grid-connected variable speed doubly-fed induction generator, and proposes a new decoupled control to replace the conventional decoupled active and reactive powers (P-Q) control. The proposed decoupled control is based on decoupling the stator active and reactive currents, in contrast with the conventional decoupled P-Q control, which is based on decoupling the stator active and reactive powers by forcing the stator d- or q-voltage to zero. The proposed decoupled control has all the advantages of the conventional decoupled P-Q control such as constant switching frequency and robustness against slip angle inaccuracy, and it has some additional advantages: The proposed control requires less machine parameters; for the controller design, it requires the stator-to-rotor turns ratio only; for the online calculation, it does not requires any machine parameter. The proposed decoupled control is more flexible and robust since the control is independent of the grid voltage orientation. It is robust against variation in the grid voltage amplitude. Several experiments are carried out using a 1.1 kW doubly-fed induction generator (DFIG), and the results support the proposed decoupled control and demonstrate some of its advantages.
Record ID
Keywords
decoupled control, doubly-fed induction generator (DFIG), grid-connected, variable speed
Subject
Suggested Citation
Ataji AB, Miura Y, Ise T, Tanaka H. A New Robust Decoupled Control of the Stator Active and Reactive Currents for Grid-Connected Doubly-Fed Induction Generators. (2018). LAPSE:2018.0913v1
Author Affiliations
Ataji AB: Graduate School of Engineering, Osaka University, 2-1 Yamada-oka, Suita, Osaka 565-0871, Japan [ORCID]
Miura Y: Graduate School of Engineering, Osaka University, 2-1 Yamada-oka, Suita, Osaka 565-0871, Japan
Ise T: Graduate School of Engineering, Osaka University, 2-1 Yamada-oka, Suita, Osaka 565-0871, Japan
Tanaka H: Osaka Gas Co., LTD, 6-19 Torishima, Konohana-ku, Osaka 554-0051, Japan
[Login] to see author email addresses.
Miura Y: Graduate School of Engineering, Osaka University, 2-1 Yamada-oka, Suita, Osaka 565-0871, Japan
Ise T: Graduate School of Engineering, Osaka University, 2-1 Yamada-oka, Suita, Osaka 565-0871, Japan
Tanaka H: Osaka Gas Co., LTD, 6-19 Torishima, Konohana-ku, Osaka 554-0051, Japan
[Login] to see author email addresses.
Journal Name
Energies
Volume
9
Issue
3
Article Number
E179
Year
2016
Publication Date
2016-03-09
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en9030179, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2018.0913v1
This Record
External Link

https://doi.org/10.3390/en9030179
Publisher Version
Download
Meta
Record Statistics
Record Views
883
Version History
[v1] (Original Submission)
Nov 27, 2018
Verified by curator on
Nov 27, 2018
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2018.0913v1
Record Owner
Calvin Tsay
Links to Related Works
