Evaluating Patterns of Building Envelope Air Leakage with Infrared Thermography
March 27, 2023
Abstract
The next-generation performance-based building energy codes are focusing on minimizing building envelope air leakage. The quantification of air leakage in buildings is typically performed with a blower door test. However, this test does not provide information about the locations of air leakage. The aim of this study is to demonstrate a method involving qualitative and quantitative components that can be used to characterize locations of air leakage with infrared thermography. Since air leakage can have a significant impact on building energy consumption in cold climates, like in Canada, this approach can quickly inform where air barrier discontinuities occurred during construction or where to selectively target air sealing efforts in existing buildings. The observations from this study are presented, based on a thermographic image analysis during a depressurized blower door test at various pressures, in an attempt to quantify the relative rates of air leakage. The results from the investigation showed that infrared thermography (IRT) was able to discern locations and infer relative ratios of air leakage. The qualitative analysis showed that areas of air leakage are more evident under higher pressure difference. The quantitative approach showed that a minimum of 25 Pa pressure difference was required to detect the air leakage in the vicinity of the window frame, as the surface temperature decreased rapidly (almost 60% of the indoor surface/outdoor air temperature difference) at this pressure. A temperature index was defined to prioritize the areas of air leakage for retrofitting purposes. Furthermore, a thermal image subtraction method was used to determine the characteristics of the cracks based on thermal patterns. Finally, the practical implication of this study, for building developers, home inspectors, property mangers, and homeowners, is the early detection of air leakage for both existing and newly constructed buildings which could result in energy and cost savings.
The next-generation performance-based building energy codes are focusing on minimizing building envelope air leakage. The quantification of air leakage in buildings is typically performed with a blower door test. However, this test does not provide information about the locations of air leakage. The aim of this study is to demonstrate a method involving qualitative and quantitative components that can be used to characterize locations of air leakage with infrared thermography. Since air leakage can have a significant impact on building energy consumption in cold climates, like in Canada, this approach can quickly inform where air barrier discontinuities occurred during construction or where to selectively target air sealing efforts in existing buildings. The observations from this study are presented, based on a thermographic image analysis during a depressurized blower door test at various pressures, in an attempt to quantify the relative rates of air leakage. The results from the investigation showed that infrared thermography (IRT) was able to discern locations and infer relative ratios of air leakage. The qualitative analysis showed that areas of air leakage are more evident under higher pressure difference. The quantitative approach showed that a minimum of 25 Pa pressure difference was required to detect the air leakage in the vicinity of the window frame, as the surface temperature decreased rapidly (almost 60% of the indoor surface/outdoor air temperature difference) at this pressure. A temperature index was defined to prioritize the areas of air leakage for retrofitting purposes. Furthermore, a thermal image subtraction method was used to determine the characteristics of the cracks based on thermal patterns. Finally, the practical implication of this study, for building developers, home inspectors, property mangers, and homeowners, is the early detection of air leakage for both existing and newly constructed buildings which could result in energy and cost savings.
Record ID
Keywords
air leakage area, infrared thermography, pressure differences, qualitative analysis, quantitative analysis
Subject
Suggested Citation
Mahmoodzadeh M, Gretka V, Wong S, Froese T, Mukhopadhyaya P. Evaluating Patterns of Building Envelope Air Leakage with Infrared Thermography. (2023). LAPSE:2023.24150
Author Affiliations
Mahmoodzadeh M: Department of Civil Engineering, University of Victoria, Victoria, BC V8W 2Y2, Canada
Gretka V: Department of Building Specialty Services, Morrison Hershfield Ltd., Victoria, BC V8W 1C6, Canada
Wong S: Department of Building Specialty Services, Morrison Hershfield Ltd., Vancouver, BC V5C 6S7, Canada
Froese T: Department of Civil Engineering, University of Victoria, Victoria, BC V8W 2Y2, Canada
Mukhopadhyaya P: Department of Civil Engineering, University of Victoria, Victoria, BC V8W 2Y2, Canada [ORCID]
Gretka V: Department of Building Specialty Services, Morrison Hershfield Ltd., Victoria, BC V8W 1C6, Canada
Wong S: Department of Building Specialty Services, Morrison Hershfield Ltd., Vancouver, BC V5C 6S7, Canada
Froese T: Department of Civil Engineering, University of Victoria, Victoria, BC V8W 2Y2, Canada
Mukhopadhyaya P: Department of Civil Engineering, University of Victoria, Victoria, BC V8W 2Y2, Canada [ORCID]
Journal Name
Energies
Volume
13
Issue
14
Article Number
E3545
Year
2020
Publication Date
2020-07-09
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en13143545, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.24150
This Record
External Link

https://doi.org/10.3390/en13143545
Publisher Version
Download
Meta
Record Statistics
Record Views
107
Version History
[v1] (Original Submission)
Mar 27, 2023
Verified by curator on
Mar 27, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
http://psecommunity.org/LAPSE:2023.24150
Record Owner
Auto Uploader for LAPSE
Links to Related Works