LAPSE:2023.15471
Published Article
LAPSE:2023.15471
Preliminary Evaluation of the Impact of Sustained Overvoltage on Low Voltage Electronics-Based Equipment
March 2, 2023
Abstract
Low voltage devices connected to public electricity supply networks can be subjected to a wide range of voltage quality, including sustained overvoltage. Assessing the impact of sustained overvoltage on devices connected to the distribution network is important in determining the appropriate variance of standard voltage levels without unduly impacting the utility and customers from a technical and economic perspective. Therefore, a clear understanding of the impact that sustained overvoltage has on the lifetime of the connected equipment is a necessary task. This paper investigates the impact of sustained overvoltage through a series of accelerated-life testing experiments on a custom designed test device representative of a common interface between the power supply and distribution network, a switch mode power supply. The switch mode power supply with combined rectifier and filtering capacitor represents one of the most common front ends of LV equipment in modern appliances, and the work here concentrates on the impact of overvoltage on capacitor ageing. The results of the testing indicate that there is an accelerated ageing impact correlated with the applied voltage magnitude. Furthermore, analysis shows that mismatches between appliance voltage rating and sustained network voltage, leading to accelerated ageing, may result in premature device failure without the consumer being aware of the root cause.
Keywords
accelerated life testing, electrolytic capacitor, power quality, sustained overvoltage, switch mode power supply
Suggested Citation
David J, Ciufo P, Elphick S, Robinson D. Preliminary Evaluation of the Impact of Sustained Overvoltage on Low Voltage Electronics-Based Equipment. (2023). LAPSE:2023.15471
Author Affiliations
David J: Australian Power Quality and Reliability Centre, University of Wollongong, Wollongong 2522, Australia [ORCID]
Ciufo P: Australian Power Quality and Reliability Centre, University of Wollongong, Wollongong 2522, Australia [ORCID]
Elphick S: Australian Power Quality and Reliability Centre, University of Wollongong, Wollongong 2522, Australia
Robinson D: Australian Power Quality and Reliability Centre, University of Wollongong, Wollongong 2522, Australia [ORCID]
Journal Name
Energies
Volume
15
Issue
4
First Page
1536
Year
2022
Publication Date
2022-02-19
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en15041536, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.15471
This Record
External Link

https://doi.org/10.3390/en15041536
Publisher Version
Download
Files
Mar 2, 2023
Main Article
License
CC BY 4.0
Meta
Record Statistics
Record Views
310
Version History
[v1] (Original Submission)
Mar 2, 2023
 
Verified by curator on
Mar 2, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
http://psecommunity.org/LAPSE:2023.15471
 
Record Owner
Auto Uploader for LAPSE
Links to Related Works
Directly Related to This Work
Publisher Version
(0.07 seconds)

[0.07 s]