Abstract
In this work, the performance of an innovative evaporator based on water falling film was investigated. The studied evaporator has been equipped with a recirculation system to maximise the wetted surface. Tests have been carried out in a lab-scale adsorption unit connected to a test bench recently realised at Politecnico di Milano labs for evaluating heat transfer performances under realistic operating conditions. Several ad/desorption cooling cycles were performed, setting different liquid refrigerant initial contents (0.9−1.5 kg), different chilled water inlet temperatures (7−20 °C) and flow rates (200−1000 L/h) and different adsorbent bed temperatures (25−30 °C). Evaporation performance has been determined in delivered cooling capacity. Moreover, the experimental data were used to calculate the overall evaporator heat transfer conductance (UA). Experiments showed how the heat duty peaks are mainly due to the thermal level of the chilled water that enters the evaporator, not the water content inside it because this value only affects the duration of the process. Instead, the UA value does not depend on the evaporator inlet chilled water temperature and initial mass content inside the evaporator. UA is 540−570 W/K for temperatures of chilled water entering the evaporator, equal to 10−20 °C, and mass of refrigerant of 0.9−1.5 kg.
In this work, the performance of an innovative evaporator based on water falling film was investigated. The studied evaporator has been equipped with a recirculation system to maximise the wetted surface. Tests have been carried out in a lab-scale adsorption unit connected to a test bench recently realised at Politecnico di Milano labs for evaluating heat transfer performances under realistic operating conditions. Several ad/desorption cooling cycles were performed, setting different liquid refrigerant initial contents (0.9−1.5 kg), different chilled water inlet temperatures (7−20 °C) and flow rates (200−1000 L/h) and different adsorbent bed temperatures (25−30 °C). Evaporation performance has been determined in delivered cooling capacity. Moreover, the experimental data were used to calculate the overall evaporator heat transfer conductance (UA). Experiments showed how the heat duty peaks are mainly due to the thermal level of the chilled water that enters the evaporator, not the water content inside it because this value only affects the duration of the process. Instead, the UA value does not depend on the evaporator inlet chilled water temperature and initial mass content inside the evaporator. UA is 540−570 W/K for temperatures of chilled water entering the evaporator, equal to 10−20 °C, and mass of refrigerant of 0.9−1.5 kg.
Record ID
Keywords
adsorption chillers, silica gel, water evaporation
Subject
Suggested Citation
Toppi T, Villa T, Vasta S, Mittelbach W, Freni A. Testing of a Falling-Film Evaporator for Adsorption Chillers. (2023). LAPSE:2023.14955
Author Affiliations
Toppi T: Department of Energy, Politecnico di Milano, Via Lambruschini 4, 20156 Milan, Italy
Villa T: Department of Energy, Politecnico di Milano, Via Lambruschini 4, 20156 Milan, Italy
Vasta S: CNR—ITAE, Consiglio Nazionale delle Ricerche-Istituto di Tecnologie Avanzate per l’Energia ‘‘Nicola Giordano’’, 98126 Messina, Italy [ORCID]
Mittelbach W: Sorption Technologies GmbH, 79144 Freiburg, Germany
Freni A: CNR ICCOM—Consiglio Nazionale delle Ricerche Istituto di Chimica dei Composti Organometallici, 56124 Pisa, Italy
Villa T: Department of Energy, Politecnico di Milano, Via Lambruschini 4, 20156 Milan, Italy
Vasta S: CNR—ITAE, Consiglio Nazionale delle Ricerche-Istituto di Tecnologie Avanzate per l’Energia ‘‘Nicola Giordano’’, 98126 Messina, Italy [ORCID]
Mittelbach W: Sorption Technologies GmbH, 79144 Freiburg, Germany
Freni A: CNR ICCOM—Consiglio Nazionale delle Ricerche Istituto di Chimica dei Composti Organometallici, 56124 Pisa, Italy
Journal Name
Energies
Volume
15
Issue
5
First Page
1709
Year
2022
Publication Date
2022-02-24
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en15051709, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.14955
This Record
External Link

https://doi.org/10.3390/en15051709
Publisher Version
Download
Meta
Record Statistics
Record Views
310
Version History
[v1] (Original Submission)
Mar 2, 2023
Verified by curator on
Mar 2, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
http://psecommunity.org/LAPSE:2023.14955
Record Owner
Auto Uploader for LAPSE
Links to Related Works
(0.09 seconds)
[0.09 s]