Numerical Prediction of Refrigerant Oil Two-Phase Flow from Scroll Compressor Discharge to the Suction Side via Back Pressure Chamber
June 21, 2024
Abstract
Oil lubricates the contact between the orbiting and stationary scroll in the refrigerant scroll compressor, while the sealing between the scrolls is achieved through the refrigerant vapour pressure in the sealed back pressure chamber. The back pressure should be adjusted using the refrigerant oil two-phase flow from the oil separator at the compressor discharge to the back pressure chamber and the refrigerant oil flow from the back pressure chamber to the compressor suction side. Both of the flows are conducted through connecting tubes with corresponding high-pressure and low-pressure nozzles with small diameters. Models for predicting the refrigerant oil critical and subcritical flows through the nozzles were developed and applied in enable the prediction of the back pressure. The models are original, because the slip between the oil and the refrigerant as well as the refrigerant solubility in the oil are taken into account. The critical flow model is validated against the experimental data that are available in the literature. The back pressure is predicted by equating the mass flow rates of refrigerant and oil two-phase mixtures through the high- and low-pressure nozzles. The results show that the critical flow takes place through the high-pressure nozzle, while the subcritical flow through the low-pressure nozzle can also exist in cases with a small pressure difference between the back pressure chamber and the compressor suction side. The refrigerant solubility in the oil has a small influence on the critical and subcritical refrigerant oil mixture mass flow rates, while the influence on the back pressure is more pronounced.
Keywords
back pressure chamber, oil, refrigerant, scroll compressor, two-phase critical flow
Suggested Citation
Stevanovic VD, Petrovic MM, Cucuz S, Milivojevic S, Ilic M. Numerical Prediction of Refrigerant Oil Two-Phase Flow from Scroll Compressor Discharge to the Suction Side via Back Pressure Chamber. (2024). LAPSE:2024.1094
Author Affiliations
Stevanovic VD: Faculty of Mechanical Engineering, University of Belgrade, Kraljice Marije 16, 11120 Belgrade, Serbia [ORCID]
Petrovic MM: Faculty of Mechanical Engineering, University of Belgrade, Kraljice Marije 16, 11120 Belgrade, Serbia [ORCID]
Cucuz S: Pierburg GmbH, Alfred-Pierburg-Straße 1, 41460 Neuss, Germany
Milivojevic S: Faculty of Mechanical Engineering, University of Belgrade, Kraljice Marije 16, 11120 Belgrade, Serbia [ORCID]
Ilic M: Innovation Center, Faculty of Mechanical Engineering, University of Belgrade, Kraljice Marije 16, 11120 Belgrade, Serbia
Journal Name
Processes
Volume
12
Issue
1
First Page
6
Year
2023
Publication Date
2023-12-19
ISSN
2227-9717
Version Comments
Original Submission
Other Meta
PII: pr12010006, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2024.1094
This Record
External Link

https://doi.org/10.3390/pr12010006
Publisher Version
Download
Files
Jun 21, 2024
Main Article
License
CC BY 4.0
Meta
Record Statistics
Record Views
230
Version History
[v1] (Original Submission)
Jun 21, 2024
 
Verified by curator on
Jun 21, 2024
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2024.1094
 
Record Owner
Auto Uploader for LAPSE
Links to Related Works
Directly Related to This Work
Publisher Version