LAPSE:2023.8993
Published Article

LAPSE:2023.8993
Optimal Allocation of Renewable Energy Sources and Battery Storage Systems Considering Energy Management System Optimization Based on Fuzzy Inference
February 27, 2023
Abstract
The main problem in planning the optimal operation of renewable energy sources and battery storage systems is the amount of data that must be considered to cover an entire observation period. If the observation period is one year, the characteristic days or averaged data (daily, weekly or monthly averages) are considered to reduce the number of data. Since the average values of the entered data differ from the actual values, it is better to work with hourly or 15-min data at the annual level. The study presents a framework for solving the problem of the optimal allocation and operation of renewable energy sources and battery storage systems. The proposed method simultaneously solves the optimal allocation and energy management problem considering hourly data at the annual level. The fuzzy inference-based system is proposed for scheduling optimal profiles of battery storage systems and renewable energy sources. The developed fuzzy inference system manages the power factors of the photovoltaic and wind power systems, the power factor and output of the biogas plant, and the operating status of the battery storage system. The presented method simultaneously finds the optimal parameters of the energy management system and the optimal allocation and operation of the renewable energy sources and the battery storage system. The developed method is based on the calculation of steady-state power flow. The proposed method is to be used in the design phase for the installation of various renewable energy sources and battery storage systems. In addition, the method is intended to be used to optimally control the power output of energy sources and the operation of energy storage systems during steady-state operation in order to operate the distribution network with minimum annual active energy losses. The developed method is applied to the test distribution system IEEE with 37 nodes. The reduction in annual energy losses in the tested distribution system is about 80% compared to the base case without renewable energy sources and battery storage system.
The main problem in planning the optimal operation of renewable energy sources and battery storage systems is the amount of data that must be considered to cover an entire observation period. If the observation period is one year, the characteristic days or averaged data (daily, weekly or monthly averages) are considered to reduce the number of data. Since the average values of the entered data differ from the actual values, it is better to work with hourly or 15-min data at the annual level. The study presents a framework for solving the problem of the optimal allocation and operation of renewable energy sources and battery storage systems. The proposed method simultaneously solves the optimal allocation and energy management problem considering hourly data at the annual level. The fuzzy inference-based system is proposed for scheduling optimal profiles of battery storage systems and renewable energy sources. The developed fuzzy inference system manages the power factors of the photovoltaic and wind power systems, the power factor and output of the biogas plant, and the operating status of the battery storage system. The presented method simultaneously finds the optimal parameters of the energy management system and the optimal allocation and operation of the renewable energy sources and the battery storage system. The developed method is based on the calculation of steady-state power flow. The proposed method is to be used in the design phase for the installation of various renewable energy sources and battery storage systems. In addition, the method is intended to be used to optimally control the power output of energy sources and the operation of energy storage systems during steady-state operation in order to operate the distribution network with minimum annual active energy losses. The developed method is applied to the test distribution system IEEE with 37 nodes. The reduction in annual energy losses in the tested distribution system is about 80% compared to the base case without renewable energy sources and battery storage system.
Record ID
Keywords
battery storage, distributed generation, energy loss reduction, fuzzy inference system, metaheuristic optimization, power distribution system
Subject
Suggested Citation
Barukčić M, Varga T, Benšić T, Jerković Štil V. Optimal Allocation of Renewable Energy Sources and Battery Storage Systems Considering Energy Management System Optimization Based on Fuzzy Inference. (2023). LAPSE:2023.8993
Author Affiliations
Barukčić M: Faculty of Electrical Engineering, Computer Science and Information Technology Osijek, Josip Juraj Strossmayer University of Osijek, 31000 Osijek, Croatia [ORCID]
Varga T: Faculty of Electrical Engineering, Computer Science and Information Technology Osijek, Josip Juraj Strossmayer University of Osijek, 31000 Osijek, Croatia [ORCID]
Benšić T: Faculty of Electrical Engineering, Computer Science and Information Technology Osijek, Josip Juraj Strossmayer University of Osijek, 31000 Osijek, Croatia [ORCID]
Jerković Štil V: Faculty of Electrical Engineering, Computer Science and Information Technology Osijek, Josip Juraj Strossmayer University of Osijek, 31000 Osijek, Croatia [ORCID]
Varga T: Faculty of Electrical Engineering, Computer Science and Information Technology Osijek, Josip Juraj Strossmayer University of Osijek, 31000 Osijek, Croatia [ORCID]
Benšić T: Faculty of Electrical Engineering, Computer Science and Information Technology Osijek, Josip Juraj Strossmayer University of Osijek, 31000 Osijek, Croatia [ORCID]
Jerković Štil V: Faculty of Electrical Engineering, Computer Science and Information Technology Osijek, Josip Juraj Strossmayer University of Osijek, 31000 Osijek, Croatia [ORCID]
Journal Name
Energies
Volume
15
Issue
19
First Page
6884
Year
2022
Publication Date
2022-09-20
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en15196884, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.8993
This Record
External Link

https://doi.org/10.3390/en15196884
Publisher Version
Download
Meta
Record Statistics
Record Views
350
Version History
[v1] (Original Submission)
Feb 27, 2023
Verified by curator on
Feb 27, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.8993
Record Owner
Auto Uploader for LAPSE
Links to Related Works
(0.07 seconds)
[0.08 s]