LAPSE:2023.8731
Published Article

LAPSE:2023.8731
A Closed-Loop Water Management Methodology for PEM Fuel Cell System Based on Impedance Information Feedback
February 24, 2023
Abstract
Water management is an important issue for proton exchange membrane fuel cells (PEMFC). The research mainly focuses on the diagnosis and treatment of faults. However, faults harm PEMFC and cause its durability decay, whatever duration they last. This study designs a closed-loop water management system to control the water content in a reasonable range which can not only avoid the faults of hydration and flooding but also improve the performance and durability of PEMFC. The proposed system introduces the measurement methodology based on the phase of single-frequency impedance, which corresponds numerically well with the water content. Moreover, two preferred operating conditions, cathode air stoichiometry and stack temperature, are adopted to regulate the water content with a trade-off between the time cost and power loss. The open-loop characteristics of water content on the temperature and air stoichiometry are studied to design the corresponding control strategy. Findings suggest that air stoichiometry is suitable for large regulation requirements of water content, while the temperature is suitable to meet small demands. Finally, the proposed closed-loop water management system is validated by experiments in variable-load and constant-load with disturbance situations. The results indicate that the proposed system effectively controls the water content within a 3% deviation from the desired value.
Water management is an important issue for proton exchange membrane fuel cells (PEMFC). The research mainly focuses on the diagnosis and treatment of faults. However, faults harm PEMFC and cause its durability decay, whatever duration they last. This study designs a closed-loop water management system to control the water content in a reasonable range which can not only avoid the faults of hydration and flooding but also improve the performance and durability of PEMFC. The proposed system introduces the measurement methodology based on the phase of single-frequency impedance, which corresponds numerically well with the water content. Moreover, two preferred operating conditions, cathode air stoichiometry and stack temperature, are adopted to regulate the water content with a trade-off between the time cost and power loss. The open-loop characteristics of water content on the temperature and air stoichiometry are studied to design the corresponding control strategy. Findings suggest that air stoichiometry is suitable for large regulation requirements of water content, while the temperature is suitable to meet small demands. Finally, the proposed closed-loop water management system is validated by experiments in variable-load and constant-load with disturbance situations. The results indicate that the proposed system effectively controls the water content within a 3% deviation from the desired value.
Record ID
Keywords
air stoichiometry, impedance, PEMFC, phase angle, temperature, water management
Subject
Suggested Citation
Xu X, Li K, Liao Z, Cao J, Wang R. A Closed-Loop Water Management Methodology for PEM Fuel Cell System Based on Impedance Information Feedback. (2023). LAPSE:2023.8731
Author Affiliations
Xu X: School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu 611731, China [ORCID]
Li K: School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu 611731, China [ORCID]
Liao Z: School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu 611731, China [ORCID]
Cao J: School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu 611731, China [ORCID]
Wang R: School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu 611731, China [ORCID]
Li K: School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu 611731, China [ORCID]
Liao Z: School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu 611731, China [ORCID]
Cao J: School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu 611731, China [ORCID]
Wang R: School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu 611731, China [ORCID]
Journal Name
Energies
Volume
15
Issue
20
First Page
7561
Year
2022
Publication Date
2022-10-13
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en15207561, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.8731
This Record
External Link

https://doi.org/10.3390/en15207561
Publisher Version
Download
Meta
Record Statistics
Record Views
378
Version History
[v1] (Original Submission)
Feb 24, 2023
Verified by curator on
Feb 24, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.8731
Record Owner
Auto Uploader for LAPSE
Links to Related Works
(0.07 seconds)
[0.07 s]