LAPSE:2023.8347
Published Article

LAPSE:2023.8347
Optimal Annual Operational Cost of a Hybrid Renewable-Based Microgrid to Increase the Power Resilience of a Critical Facility
February 24, 2023
Abstract
With the rapid increment of power outages related to extreme natural disasters such as wildfires and severe storms, microgrids have the potential to enhance resilience locally. Traditionally, grid-connected microgrids are investigated from an economic perspective only, without focusing on resilience solutions benefits during grid interruptions. Hence, the presented work proposes a technical and economic evaluation of an airport grid-connected microgrid consisting of solar photovoltaic (PV), energy storage system, and diesel generator to enhance airport power resilience under different power interruption scenarios. A modified mixed-integer linear programming scheme was introduced to minimize the total annual operating cost of the proposed resilient system. The optimal resilient microgrid components sizing and dispatching were investigated with and without a monetary assigned value for resilience as a service. Moreover, the microgrid survivability during solar performance change was investigated. The possible load increment from electric ground support equipment deployment was considered. The results show that the proposed microgrid can achieve an annual operational cost reduction while ensuring a continuous power supply for all considered outage scenarios. The operational cost saving varies between 20% and 22%. The duration of the outage and critical load level have a higher impact on microgrid sizing and dispatching.
With the rapid increment of power outages related to extreme natural disasters such as wildfires and severe storms, microgrids have the potential to enhance resilience locally. Traditionally, grid-connected microgrids are investigated from an economic perspective only, without focusing on resilience solutions benefits during grid interruptions. Hence, the presented work proposes a technical and economic evaluation of an airport grid-connected microgrid consisting of solar photovoltaic (PV), energy storage system, and diesel generator to enhance airport power resilience under different power interruption scenarios. A modified mixed-integer linear programming scheme was introduced to minimize the total annual operating cost of the proposed resilient system. The optimal resilient microgrid components sizing and dispatching were investigated with and without a monetary assigned value for resilience as a service. Moreover, the microgrid survivability during solar performance change was investigated. The possible load increment from electric ground support equipment deployment was considered. The results show that the proposed microgrid can achieve an annual operational cost reduction while ensuring a continuous power supply for all considered outage scenarios. The operational cost saving varies between 20% and 22%. The duration of the outage and critical load level have a higher impact on microgrid sizing and dispatching.
Record ID
Keywords
airport, ground support equipment, microgrid, renewable energy technologies, resilience
Subject
Suggested Citation
Alruwaili M, Cipcigan L. Optimal Annual Operational Cost of a Hybrid Renewable-Based Microgrid to Increase the Power Resilience of a Critical Facility. (2023). LAPSE:2023.8347
Author Affiliations
Alruwaili M: School of Engineering, Cardiff University, Cardiff CF24 3AA, UK; Faculty of Engineering, Northern Border University, P.O. Box 1321, Arar 91431, Saudi Arabia [ORCID]
Cipcigan L: School of Engineering, Cardiff University, Cardiff CF24 3AA, UK
Cipcigan L: School of Engineering, Cardiff University, Cardiff CF24 3AA, UK
Journal Name
Energies
Volume
15
Issue
21
First Page
8040
Year
2022
Publication Date
2022-10-28
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en15218040, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.8347
This Record
External Link

https://doi.org/10.3390/en15218040
Publisher Version
Download
Meta
Record Statistics
Record Views
184
Version History
[v1] (Original Submission)
Feb 24, 2023
Verified by curator on
Feb 24, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.8347
Record Owner
Auto Uploader for LAPSE
Links to Related Works