LAPSE:2023.8241
Published Article

LAPSE:2023.8241
Thermal Electrical Tests for Battery Safety Standardization
February 24, 2023
Abstract
Battery safety tests are defined by several international standards in different ways and with heterogenous termination and failure criteria. In this work, lithium-ion cells were examined regarding their behavior in the event of overcharging and also in the event of an external short circuit with varied parameters specified by standards. The voltage, current, and temperature curves were evaluated. In addition, the changes in the cells were analyzed using electrochemical impedance spectroscopy (EIS). It is shown that the cells exhibit reproducible behavior in a clamped state. Further, it could be determined that the position of the cell opening during an overcharge has an influence on the further behavior of the cell. EIS data showed that the cells have a significantly higher internal resistance after an overcharge. The short-circuit tests at different ambient temperatures indicated that the internal resistance of the cell decreases with increasing temperature. However, no reproducible effects in impedance spectra were present after the short-circuit test. This work illustrates that the choice of test parameters and termination criteria undoubtedly influence the test results and thus may change the classification of cells as either safe or unsafe. Thus, cells may be classified as safe regarding a certain standard but unsafe regarding another.
Battery safety tests are defined by several international standards in different ways and with heterogenous termination and failure criteria. In this work, lithium-ion cells were examined regarding their behavior in the event of overcharging and also in the event of an external short circuit with varied parameters specified by standards. The voltage, current, and temperature curves were evaluated. In addition, the changes in the cells were analyzed using electrochemical impedance spectroscopy (EIS). It is shown that the cells exhibit reproducible behavior in a clamped state. Further, it could be determined that the position of the cell opening during an overcharge has an influence on the further behavior of the cell. EIS data showed that the cells have a significantly higher internal resistance after an overcharge. The short-circuit tests at different ambient temperatures indicated that the internal resistance of the cell decreases with increasing temperature. However, no reproducible effects in impedance spectra were present after the short-circuit test. This work illustrates that the choice of test parameters and termination criteria undoubtedly influence the test results and thus may change the classification of cells as either safe or unsafe. Thus, cells may be classified as safe regarding a certain standard but unsafe regarding another.
Record ID
Keywords
battery safety, lithium-ion battery, overcharging, short circuit, standardization
Subject
Suggested Citation
Stein A, Kehl D, Jackmann C, Essmann S, Lienesch F, Kurrat M. Thermal Electrical Tests for Battery Safety Standardization. (2023). LAPSE:2023.8241
Author Affiliations
Stein A: Physikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, 38116 Braunschweig, Germany [ORCID]
Kehl D: Elenia Institute for High Voltage Technology and Power Systems, Technische Universität Braunschweig, Schleinitzstraße 23, 38106 Braunschweig, Germany [ORCID]
Jackmann C: Elenia Institute for High Voltage Technology and Power Systems, Technische Universität Braunschweig, Schleinitzstraße 23, 38106 Braunschweig, Germany
Essmann S: Physikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, 38116 Braunschweig, Germany [ORCID]
Lienesch F: Physikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, 38116 Braunschweig, Germany [ORCID]
Kurrat M: Elenia Institute for High Voltage Technology and Power Systems, Technische Universität Braunschweig, Schleinitzstraße 23, 38106 Braunschweig, Germany
Kehl D: Elenia Institute for High Voltage Technology and Power Systems, Technische Universität Braunschweig, Schleinitzstraße 23, 38106 Braunschweig, Germany [ORCID]
Jackmann C: Elenia Institute for High Voltage Technology and Power Systems, Technische Universität Braunschweig, Schleinitzstraße 23, 38106 Braunschweig, Germany
Essmann S: Physikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, 38116 Braunschweig, Germany [ORCID]
Lienesch F: Physikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, 38116 Braunschweig, Germany [ORCID]
Kurrat M: Elenia Institute for High Voltage Technology and Power Systems, Technische Universität Braunschweig, Schleinitzstraße 23, 38106 Braunschweig, Germany
Journal Name
Energies
Volume
15
Issue
21
First Page
7930
Year
2022
Publication Date
2022-10-26
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en15217930, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.8241
This Record
External Link

https://doi.org/10.3390/en15217930
Publisher Version
Download
Meta
Record Statistics
Record Views
170
Version History
[v1] (Original Submission)
Feb 24, 2023
Verified by curator on
Feb 24, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.8241
Record Owner
Auto Uploader for LAPSE
Links to Related Works
(0.34 seconds) 0.02 + 0.02 + 0.15 + 0.07 + 0 + 0.02 + 0.01 + 0 + 0.02 + 0.02 + 0 + 0