LAPSE:2023.8102
Published Article

LAPSE:2023.8102
Flow-Induced Vibration of Non-Rotating Structures of a High-Head Pump-Turbine during Start-Up in Turbine Mode
February 24, 2023
Abstract
Pumped storage-power plants play an extremely important role in the modern smart grid due to their irreplaceable advantages in load peak-valley regulation, frequency modulation, and phase modulation. The number of start-stops per day of pump-turbine units is therefore also increasing. During the start-up transient process in turbine mode, the complex flow in runner passage, crown and band chambers, and seal labyrinth is able to induce severe vibration of non-rotating structures such as head cover, stay-ring, and pose a threat to the safe operation of the pump-turbine unit. In this article, the flow-induced vibration of the structures of a pump-turbine unit during its start-up process in turbine mode is studied. In the first place, this investigation establishes a three-dimensional model of the full flow passage and carries out a full three-dimensional CFD calculation based on one-dimensional pipeline calculation results for the start-up transient process. In the next place, by applying the fluid−structure interaction calculation method, the finite element analysis of non-rotating components of the pump-turbine unit is carried out. The flow-induced stresses and deformations of head cover, stay-ring, etc., are obtained and analyzed. The results reveal that the maximum deformation of the non-rotating structures is located at the inner edge of the head cover while the maximum stress appears at the trailing edge fillet of a stay vane. In summary, the dynamic stress of the non-rotating structures changes largely during the start-up process. The stress is strongly related to the axial thrust caused by the fluid flow. The achieved results can provide guidance for further fatigue life assessment of non-rotating structures and contribute to the structural safety design of pump-turbine units.
Pumped storage-power plants play an extremely important role in the modern smart grid due to their irreplaceable advantages in load peak-valley regulation, frequency modulation, and phase modulation. The number of start-stops per day of pump-turbine units is therefore also increasing. During the start-up transient process in turbine mode, the complex flow in runner passage, crown and band chambers, and seal labyrinth is able to induce severe vibration of non-rotating structures such as head cover, stay-ring, and pose a threat to the safe operation of the pump-turbine unit. In this article, the flow-induced vibration of the structures of a pump-turbine unit during its start-up process in turbine mode is studied. In the first place, this investigation establishes a three-dimensional model of the full flow passage and carries out a full three-dimensional CFD calculation based on one-dimensional pipeline calculation results for the start-up transient process. In the next place, by applying the fluid−structure interaction calculation method, the finite element analysis of non-rotating components of the pump-turbine unit is carried out. The flow-induced stresses and deformations of head cover, stay-ring, etc., are obtained and analyzed. The results reveal that the maximum deformation of the non-rotating structures is located at the inner edge of the head cover while the maximum stress appears at the trailing edge fillet of a stay vane. In summary, the dynamic stress of the non-rotating structures changes largely during the start-up process. The stress is strongly related to the axial thrust caused by the fluid flow. The achieved results can provide guidance for further fatigue life assessment of non-rotating structures and contribute to the structural safety design of pump-turbine units.
Record ID
Keywords
flow-induced vibration, non-rotating structures, pump-turbine, start-up, turbine mode
Subject
Suggested Citation
Yang M, Zhao W, Bi H, Yang H, He Q, Huang X, Wang Z. Flow-Induced Vibration of Non-Rotating Structures of a High-Head Pump-Turbine during Start-Up in Turbine Mode. (2023). LAPSE:2023.8102
Author Affiliations
Yang M: Branch Company of Maintenance & Test, CSG Power Generation Co., Ltd., Guangzhou 511400, China
Zhao W: State Key Laboratory of Hydroscience and Engineering, Tsinghua University, Beijing 100084, China [ORCID]
Bi H: State Key Laboratory of Hydroscience and Engineering, Tsinghua University, Beijing 100084, China
Yang H: Branch Company of Maintenance & Test, CSG Power Generation Co., Ltd., Guangzhou 511400, China
He Q: State Key Laboratory of Hydroscience and Engineering, Tsinghua University, Beijing 100084, China [ORCID]
Huang X: S.C.I. Energy, Future Energy Research Institute, Seidengasse 17, 8706 Zurich, Switzerland [ORCID]
Wang Z: State Key Laboratory of Hydroscience and Engineering, Tsinghua University, Beijing 100084, China [ORCID]
Zhao W: State Key Laboratory of Hydroscience and Engineering, Tsinghua University, Beijing 100084, China [ORCID]
Bi H: State Key Laboratory of Hydroscience and Engineering, Tsinghua University, Beijing 100084, China
Yang H: Branch Company of Maintenance & Test, CSG Power Generation Co., Ltd., Guangzhou 511400, China
He Q: State Key Laboratory of Hydroscience and Engineering, Tsinghua University, Beijing 100084, China [ORCID]
Huang X: S.C.I. Energy, Future Energy Research Institute, Seidengasse 17, 8706 Zurich, Switzerland [ORCID]
Wang Z: State Key Laboratory of Hydroscience and Engineering, Tsinghua University, Beijing 100084, China [ORCID]
Journal Name
Energies
Volume
15
Issue
22
First Page
8743
Year
2022
Publication Date
2022-11-21
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en15228743, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.8102
This Record
External Link

https://doi.org/10.3390/en15228743
Publisher Version
Download
Meta
Record Statistics
Record Views
366
Version History
[v1] (Original Submission)
Feb 24, 2023
Verified by curator on
Feb 24, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.8102
Record Owner
Auto Uploader for LAPSE
Links to Related Works
(0.07 seconds)
[0.07 s]