Abstract
To reduce the on-peak electrical power consumption, storage devices are widely performed with the help of an energy management system. According to IEA, residential air conditioning consumes 70% of the electricity, increasing by 4% every year. To minimize peak power consumption, thermal energy storage (TES) can be used to store cooled water for the air conditioning system. An efficient chilled water tank was designed and computationally investigated. Three-dimensional cylindrical tanks were simulated with seven different heights to diameter (H:D) ratios. At first, the temperature changes in a chilled water tank during discharging and charging periods were studied. An 11-h charging period was carried out during the off-peak time at night, while the discharging period was 13 h during the daytime. Under time constraints regarding peak and off-peak periods, a tank with an H:D = 2.0 can only be used for 13-h discharging. Then the chilled water was simulated with a set temperature of 4 °C during the charging. This resulted in the system being usable for six days, after which it had to be stopped for longer charging. A storage tank with an H:D ratio of 2.0 was found to be suitable for an air conditioning system. If six days of operations (one day off) were used, it could save 15.38% of electrical energy consumption and 51.65% of electricity cost. This saving leads to a 5.55-year payback period.
To reduce the on-peak electrical power consumption, storage devices are widely performed with the help of an energy management system. According to IEA, residential air conditioning consumes 70% of the electricity, increasing by 4% every year. To minimize peak power consumption, thermal energy storage (TES) can be used to store cooled water for the air conditioning system. An efficient chilled water tank was designed and computationally investigated. Three-dimensional cylindrical tanks were simulated with seven different heights to diameter (H:D) ratios. At first, the temperature changes in a chilled water tank during discharging and charging periods were studied. An 11-h charging period was carried out during the off-peak time at night, while the discharging period was 13 h during the daytime. Under time constraints regarding peak and off-peak periods, a tank with an H:D = 2.0 can only be used for 13-h discharging. Then the chilled water was simulated with a set temperature of 4 °C during the charging. This resulted in the system being usable for six days, after which it had to be stopped for longer charging. A storage tank with an H:D ratio of 2.0 was found to be suitable for an air conditioning system. If six days of operations (one day off) were used, it could save 15.38% of electrical energy consumption and 51.65% of electricity cost. This saving leads to a 5.55-year payback period.
Record ID
Keywords
efficient air-conditioning, energy management, energy saving, green batteries, on-peak power reduction
Subject
Suggested Citation
Tipasri W, Suksri A, Velmurugan K, Wongwuttanasatian T. Energy Management for an Air Conditioning System Using a Storage Device to Reduce the On-Peak Power Consumption. (2023). LAPSE:2023.7389
Author Affiliations
Tipasri W: Department of Mechanical Engineering, Faculty of Engineering, Khon Kaen University, 123 Mittrapharp Rd., Khon Kaen 40002, Thailand; Centre for Alternative Energy Research and Development, Khon Kaen University, 123 Mittrapharp Rd., Khon Kaen 40002, Thailan
Suksri A: Centre for Alternative Energy Research and Development, Khon Kaen University, 123 Mittrapharp Rd., Khon Kaen 40002, Thailand
Velmurugan K: Department of Mechanical Engineering, Faculty of Engineering, Khon Kaen University, 123 Mittrapharp Rd., Khon Kaen 40002, Thailand; Centre for Alternative Energy Research and Development, Khon Kaen University, 123 Mittrapharp Rd., Khon Kaen 40002, Thailan
Wongwuttanasatian T: Department of Mechanical Engineering, Faculty of Engineering, Khon Kaen University, 123 Mittrapharp Rd., Khon Kaen 40002, Thailand; Centre for Alternative Energy Research and Development, Khon Kaen University, 123 Mittrapharp Rd., Khon Kaen 40002, Thailan [ORCID]
Suksri A: Centre for Alternative Energy Research and Development, Khon Kaen University, 123 Mittrapharp Rd., Khon Kaen 40002, Thailand
Velmurugan K: Department of Mechanical Engineering, Faculty of Engineering, Khon Kaen University, 123 Mittrapharp Rd., Khon Kaen 40002, Thailand; Centre for Alternative Energy Research and Development, Khon Kaen University, 123 Mittrapharp Rd., Khon Kaen 40002, Thailan
Wongwuttanasatian T: Department of Mechanical Engineering, Faculty of Engineering, Khon Kaen University, 123 Mittrapharp Rd., Khon Kaen 40002, Thailand; Centre for Alternative Energy Research and Development, Khon Kaen University, 123 Mittrapharp Rd., Khon Kaen 40002, Thailan [ORCID]
Journal Name
Energies
Volume
15
Issue
23
First Page
8940
Year
2022
Publication Date
2022-11-25
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en15238940, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.7389
This Record
External Link

https://doi.org/10.3390/en15238940
Publisher Version
Download
Meta
Record Statistics
Record Views
208
Version History
[v1] (Original Submission)
Feb 24, 2023
Verified by curator on
Feb 24, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.7389
Record Owner
Auto Uploader for LAPSE
Links to Related Works