Using a Mine Dewatering System to Increase Cooling Capacity and Energy Recovery of Underground Refrigeration Plant: A Case Study
Dariusz Obracaj, Nikodem Szlązak, Marek Korzec
February 24, 2023
Heat stress in deep hot mines is a factor that often determines the possibility of technical mining of natural resources. One of the solutions enabling miners to work in such mines is air cooling. Cooling systems vary, and their selection depends on the type of mine and the mining methods used. Limited air cooling capabilities exist in electric-powered coal mines. The main solution for air cooling is based on movable spot air coolers. Such systems commonly use surface or underground refrigeration plants. An underground refrigeration plant (URP) equipped with compressor chillers does not achieve more than 2.5−3.0 MW of cooling capacity due to the limited heat rejection capacity of return air streams in a typical coal mine. The method discussed in this paper, using mine water to discharge waste heat from the underground refrigeration plant, provides a measurable benefit for optimizing the mine air cooling system. The main purpose of this research is to study the feasibility and effect of water diversion from the actual mine drainage system to the underground refrigeration plant. The water drainage system in an underground mine is called the dewatering system of the mine. The heated water in the condensers of the chillers is directed back to the mine’s central dewatering system. The recovery from water discharged to the surface contributes to optimising energy consumption for a mine air cooling and the sustainable discharge of wastewater. In addition, using the total water flow from the mine dewatering system to reject heat in compressor chillers, compared with the traditional solution, can improve the cooling capacity of URP. These findings may provide beneficial guidance for practical applications in deep hot mines with small natural water inflow.
Keywords
heat pumps, mine air cooling systems, mine dewatering system, underground refrigeration plant, waste heat recovery
Suggested Citation
Obracaj D, Szlązak N, Korzec M. Using a Mine Dewatering System to Increase Cooling Capacity and Energy Recovery of Underground Refrigeration Plant: A Case Study. (2023). LAPSE:2023.7065
Author Affiliations
Obracaj D: Faculty of Civil Engineering and Resource Management, AGH University of Science and Technology, Mickiewicza 30 Av., 30-059 Kraków, Poland [ORCID]
Szlązak N: Faculty of Civil Engineering and Resource Management, AGH University of Science and Technology, Mickiewicza 30 Av., 30-059 Kraków, Poland
Korzec M: Faculty of Civil Engineering and Resource Management, AGH University of Science and Technology, Mickiewicza 30 Av., 30-059 Kraków, Poland [ORCID]
Journal Name
Energies
Volume
15
Issue
24
First Page
9481
Year
2022
Publication Date
2022-12-14
Published Version
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en15249481, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.7065
This Record
External Link

doi:10.3390/en15249481
Publisher Version
Download
Files
[Download 1v1.pdf] (4.1 MB)
Feb 24, 2023
Main Article
License
CC BY 4.0
Meta
Record Statistics
Record Views
50
Version History
[v1] (Original Submission)
Feb 24, 2023
 
Verified by curator on
Feb 24, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.7065
 
Original Submitter
Auto Uploader for LAPSE
Links to Related Works
Directly Related to This Work
Publisher Version