Abstract
A gravity-type heat pipe boiling characteristics test rig was constructed to solve the heat dissipation problem of fuel cells during operation. The boiling heat transfer characteristics of water in a parallel plate under negative pressure at different inclination angles and heat flow density input are investigated. The results show that: First, the gravity-type heat pipe can dissipate some heat and it is possible to use it for fuel cell heat dissipation. Second, with a certain range of heat flow density, the temperature of all parts of the plate is about 80 °C, with a small temperature difference, which is conducive to the safe operation of the fuel cell. Third, the heat flow density is in the range of 2222~3111 W·m−2, the temperature difference is large, and the outlet temperature is greater than 80 °C, which exceeds the operating temperature of the fuel cell, and the power-type heat pipe should be used for heat dissipation. Fourth, the average temperature of the plate placed at an inclination angle of 45°~60° is lower compared to other angles, and the temperature is evenly distributed. On the one hand, the conclusions reveal the characteristics of boiling heat exchange under negative pressure conditions of water inside the flat plate and, on the other hand, provide a reference for designing heat pipe systems for fuel cell heat dissipation.
A gravity-type heat pipe boiling characteristics test rig was constructed to solve the heat dissipation problem of fuel cells during operation. The boiling heat transfer characteristics of water in a parallel plate under negative pressure at different inclination angles and heat flow density input are investigated. The results show that: First, the gravity-type heat pipe can dissipate some heat and it is possible to use it for fuel cell heat dissipation. Second, with a certain range of heat flow density, the temperature of all parts of the plate is about 80 °C, with a small temperature difference, which is conducive to the safe operation of the fuel cell. Third, the heat flow density is in the range of 2222~3111 W·m−2, the temperature difference is large, and the outlet temperature is greater than 80 °C, which exceeds the operating temperature of the fuel cell, and the power-type heat pipe should be used for heat dissipation. Fourth, the average temperature of the plate placed at an inclination angle of 45°~60° is lower compared to other angles, and the temperature is evenly distributed. On the one hand, the conclusions reveal the characteristics of boiling heat exchange under negative pressure conditions of water inside the flat plate and, on the other hand, provide a reference for designing heat pipe systems for fuel cell heat dissipation.
Record ID
Keywords
fuel cell, heat pipe, negative pressure, parallel plate
Subject
Suggested Citation
Jin L, Wang S, Guo J, Li H, Tian X. Performance Study of Gravity-Type Heat Pipe Applied to Fuel Cell Heat Dissipation. (2023). LAPSE:2023.6841
Author Affiliations
Jin L: College of Mechanical and Electrical Engineering, Qingdao University, Qingdao 266071, China
Wang S: College of Mechanical and Electrical Engineering, Qingdao University, Qingdao 266071, China
Guo J: College of Mechanical and Electrical Engineering, Qingdao University, Qingdao 266071, China
Li H: College of Mechanical and Electrical Engineering, Qingdao University, Qingdao 266071, China
Tian X: College of Mechanical and Electrical Engineering, Qingdao University, Qingdao 266071, China
Wang S: College of Mechanical and Electrical Engineering, Qingdao University, Qingdao 266071, China
Guo J: College of Mechanical and Electrical Engineering, Qingdao University, Qingdao 266071, China
Li H: College of Mechanical and Electrical Engineering, Qingdao University, Qingdao 266071, China
Tian X: College of Mechanical and Electrical Engineering, Qingdao University, Qingdao 266071, China
Journal Name
Energies
Volume
16
Issue
1
First Page
563
Year
2023
Publication Date
2023-01-03
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en16010563, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.6841
This Record
External Link

https://doi.org/10.3390/en16010563
Publisher Version
Download
Meta
Record Statistics
Record Views
261
Version History
[v1] (Original Submission)
Feb 24, 2023
Verified by curator on
Feb 24, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.6841
Record Owner
Auto Uploader for LAPSE
Links to Related Works
[0.21 s]