Abstract
Glycerol is a major byproduct obtained in the production of biodiesel, an important renewable fuel. The presence of free glycerol in fuel can have structural and performance consequences with respect to the engine, making fuel quality control important. The standard method to analyze glycerol in biodiesel is gas chromatography, a time-consuming and expensive technique. In this context, an electrode based on glassy carbon electrodes (GCEs) modified with reduced graphene oxide and core-shell gold@palladium nanoparticles was developed for the determination of glycerol in biodiesel. The free glycerol analysis was performed in the aqueous phase obtained by liquid−liquid extraction from a biodiesel sample. Cyclic voltammetry was chosen as the method for glycerol electrochemical analysis to regenerate active sites and promote greater sensor stability. The modified Au@Pd/rGO/GCE electrode showed an excellent performance, obtaining a linear range of 18.2 to 109 µmol L−1 with a correlation coefficient of 0.9895, limits of detection and quantification of 5.33 and 17.6 µmol L−1, respectively, high stability during 1000 cycles, and recovery values of 86% and 87% in the quantification of glycerol in biodiesel samples. The proposed method proved to be a great alternative for the analysis of glycerol in biodiesel, being a fast, sensitive, and low-cost technique due to its high stability and the use of small quantities of reagents.
Keywords
core-shell gold@palladium nanoparticles, cyclic voltammetry, glycerol, reduced graphene oxide
Subject
Suggested Citation
Paiva VM, Assis KLDSC, Archanjo BS, Ferreira DR, Senna CA, Ribeiro ES, Achete CA, D'Elia E. Electrochemical Analysis of Free Glycerol in Biodiesel Using Reduced Graphene Oxide and Gold/Palladium Core-Shell Nanoparticles Modified Glassy Carbon Electrode. (2023). LAPSE:2023.5383
Author Affiliations
Paiva VM: Institute of Chemistry, Federal University of Rio de Janeiro, University City, Rio de Janeiro 21941-909, Brazil [ORCID]
Assis KLDSC: National Institute of Metrology, Quality and Technology, Duque de Caxias 25250-020, Brazil
Archanjo BS: National Institute of Metrology, Quality and Technology, Duque de Caxias 25250-020, Brazil [ORCID]
Ferreira DR: Institute of Chemistry, Federal University of Rio de Janeiro, University City, Rio de Janeiro 21941-909, Brazil
Senna CA: National Institute of Metrology, Quality and Technology, Duque de Caxias 25250-020, Brazil
Ribeiro ES: Institute of Chemistry, Federal University of Rio de Janeiro, University City, Rio de Janeiro 21941-909, Brazil [ORCID]
Achete CA: National Institute of Metrology, Quality and Technology, Duque de Caxias 25250-020, Brazil
D'Elia E: Institute of Chemistry, Federal University of Rio de Janeiro, University City, Rio de Janeiro 21941-909, Brazil
Journal Name
Processes
Volume
9
Issue
8
First Page
1389
Year
2021
Publication Date
2021-08-10
ISSN
2227-9717
Version Comments
Original Submission
Other Meta
PII: pr9081389, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.5383
This Record
External Link

https://doi.org/10.3390/pr9081389
Publisher Version
Download
Files
Feb 23, 2023
Main Article
License
CC BY 4.0
Meta
Record Statistics
Record Views
248
Version History
[v1] (Original Submission)
Feb 23, 2023
 
Verified by curator on
Feb 23, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.5383
 
Record Owner
Auto Uploader for LAPSE
Links to Related Works
Directly Related to This Work
Publisher Version
(0.07 seconds)

[0.07 s]