LAPSE:2023.4137
Published Article
LAPSE:2023.4137
Quantitative Evaluation of the “Non-Enclosed” Microseismic Array: A Case Study in a Deeply Buried Twin-Tube Tunnel
Hang Zhang, Chunchi Ma, Tianbin Li
February 22, 2023
Abstract
The high-stress hazards of underground engineering have stimulated the exploration of microseismic monitoring and early warning methods. To achieve a good monitoring effect, the monitoring object is usually enclosed by a microseismic array (sensor array) (e.g., slope engineering, etc.). However, some characteristics of a buried tunnel, including “linear”, “deep-buried”, and “long”, make it difficult to deploy a reasonable microseismic array, which leads to the microseismic array being non-enclosed for the monitoring object. Application of the non-enclosed microseismic array yields decreases the accuracy of the source location. To solve the problem wisely, this paper deals with the feasibility of non-enclosed microseismic arrays (axial-extended, lateral-extended, and twin-tube arrays) by introducing a quantitative method. To this end, an optimized microseismic array with the best source location accuracy for a twin-tube expressway tunnel is proposed. The obtained results reveal that the non-enclosed microseismic arrays, which are unavoidable in expressway tunnel engineering, do not introduce errors but reduce the ability to resist them. Further, the twin-tube array achieves a better source location accuracy than the axial and lateral-extended arrays. In the application of the source location based on the particle swarm optimization (PSO) algorithm to the twin-tube array, microseismic events, which cluster in the rockburst section, are wholly gathered, and the maximum error is reduced by about 30−50 m, indicating its greater feasibility with respect to the single-tube array.
Keywords
microseismic monitoring, non-enclosed array, source location accuracy, twin-tube tunnel
Suggested Citation
Zhang H, Ma C, Li T. Quantitative Evaluation of the “Non-Enclosed” Microseismic Array: A Case Study in a Deeply Buried Twin-Tube Tunnel. (2023). LAPSE:2023.4137
Author Affiliations
Zhang H: State Key Laboratory of Geohazard Prevention and Geoenvironment Protection, Chengdu University of Technology, Chengdu 610059, China; College of Environment and Civil Engineering, Chengdu University of Technology, Chengdu 610059, China [ORCID]
Ma C: State Key Laboratory of Geohazard Prevention and Geoenvironment Protection, Chengdu University of Technology, Chengdu 610059, China; College of Environment and Civil Engineering, Chengdu University of Technology, Chengdu 610059, China [ORCID]
Li T: State Key Laboratory of Geohazard Prevention and Geoenvironment Protection, Chengdu University of Technology, Chengdu 610059, China; College of Environment and Civil Engineering, Chengdu University of Technology, Chengdu 610059, China
[Login] to see author email addresses.
Journal Name
Energies
Volume
12
Issue
10
Article Number
E2006
Year
2019
Publication Date
2019-05-25
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en12102006, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.4137
This Record
External Link

https://doi.org/10.3390/en12102006
Publisher Version
Download
Files
Feb 22, 2023
Main Article
License
CC BY 4.0
Meta
Record Statistics
Record Views
258
Version History
[v1] (Original Submission)
Feb 22, 2023
 
Verified by curator on
Feb 22, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.4137
 
Record Owner
Auto Uploader for LAPSE
Links to Related Works
Directly Related to This Work
Publisher Version

[0.22 s]