Cross Test Comparison in Transformer Windings Frequency Response Analysis
February 22, 2023
Abstract
Frequency Response Analysis (FRA) is an important tool used for diagnostic measurements of power transformers. Standard test configuration applied in the industry is the end-to-end open test setup; however, an interwinding capacitive configuration is also used. This paper presents a method—Cross Test Comparison (CTC)—for simultaneous analysis of results coming from both the mentioned test setups. Such an approach could offer a more sensitive tool for detecting some faults; moreover, it takes into consideration the influence of both voltage sides of a transformer in a one test result. The authors have used several indices to quantitatively assess the test results and proposed new approach to data interpretation. CTC method was tested using data from measurements performed in three cases: a unit tested in laboratory with introduced controlled deformations; transformers measured under industrial conditions; and a transformer with FRA changes resulting from tap-changer operations. The results showed that CTC method is more effective at detecting faults on the basis of FRA measurements.
Frequency Response Analysis (FRA) is an important tool used for diagnostic measurements of power transformers. Standard test configuration applied in the industry is the end-to-end open test setup; however, an interwinding capacitive configuration is also used. This paper presents a method—Cross Test Comparison (CTC)—for simultaneous analysis of results coming from both the mentioned test setups. Such an approach could offer a more sensitive tool for detecting some faults; moreover, it takes into consideration the influence of both voltage sides of a transformer in a one test result. The authors have used several indices to quantitatively assess the test results and proposed new approach to data interpretation. CTC method was tested using data from measurements performed in three cases: a unit tested in laboratory with introduced controlled deformations; transformers measured under industrial conditions; and a transformer with FRA changes resulting from tap-changer operations. The results showed that CTC method is more effective at detecting faults on the basis of FRA measurements.
Record ID
Keywords
frequency response analysis, Frequency Response Analysis (FRA), numerical indices, transformer windings
Suggested Citation
Banaszak S, Szoka W. Cross Test Comparison in Transformer Windings Frequency Response Analysis. (2023). LAPSE:2023.3960
Author Affiliations
Banaszak S: Department of Electrotechnology and Diagnostics, West Pomeranian University of Technology in Szczecin, ul. Sikorskiego 37, 70-313 Szczecin, Poland
Szoka W: Department of Electrotechnology and Diagnostics, West Pomeranian University of Technology in Szczecin, ul. Sikorskiego 37, 70-313 Szczecin, Poland
[Login] to see author email addresses.
Szoka W: Department of Electrotechnology and Diagnostics, West Pomeranian University of Technology in Szczecin, ul. Sikorskiego 37, 70-313 Szczecin, Poland
[Login] to see author email addresses.
Journal Name
Energies
Volume
11
Issue
6
Article Number
E1349
Year
2018
Publication Date
2018-05-25
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en11061349, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.3960
This Record
External Link

https://doi.org/10.3390/en11061349
Publisher Version
Download
Meta
Record Statistics
Record Views
209
Version History
[v1] (Original Submission)
Feb 22, 2023
Verified by curator on
Feb 22, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.3960
Record Owner
Auto Uploader for LAPSE
Links to Related Works