UV lamps are being increasingly used in the treatment of swimming pool water, mainly due to their abilities to disinfect and effectively remove chloramines (combined chlorine). However, the application of UV lamps in a closed loop system, such as that in which swimming pool water is treated, creates conditions under which chlorinated water is then also irradiated with UV. Thus, the advanced oxidation process occurs, which affects the transformation of organic matter and its increased reactivity, and hence the higher usage of chlorine disinfectant. In addition, UV lamps require electrical power and the periodic replacement of filaments. In order to assess whether the application of a low-pressure UV lamp is justified, water quality tests and an analysis of the operating costs (including the energy consumption) of the water treatment system were carried out for two operation variants—those of the low-pressure UV lamp being turned on and off. The experiments were carried out on the real object of the AGH University of Science and Technology sports swimming pool for one year. The consumption of electricity and water treatment reagents was also measured. The following values of the selected parameters of the swimming pool water quality were observed (for without and with UV lamp, respectively): 0.68 and 0.52 mg/L combined chlorine; 3.12 and 3.02 mg/L dissolved organic carbon; 15.70 and 15.26 µg/L trihalomethanes; 7 and 6 cfu/mL mesophilic bacteria; and 6 and 20 cfu/mL psychrophilic bacteria. Generally, the statistically important differences in water quality parameters were not observed, thus the application of the low-pressure UV lamp in the swimming pool water treatment technology did not bring the expected improvement in water quality. However, the higher consumption of electric energy (by 29%) and chlorine disinfectant (by 15%), and the need to periodically replace the lamp filaments significantly increased the operating costs of the water treatment system (by 21%) and its ecological impact, thus this technology cannot be considered as profitable or ecological.
Keywords
disinfection by-products, energy savings, operating costs, swimming pool water, UV radiation
Suggested Citation
Włodyka-Bergier A, Bergier T. Impact of Low-Pressure UV Lamp on Swimming Pool Water Quality and Operating Costs. (2023). LAPSE:2023.33950
Author Affiliations
Włodyka-Bergier A: Department of Environmental Management and Protection, Faculty of Mining Surveying and Environmental Engineering, AGH University of Science and Technology, al. Mickiewicza 30, 30-059 Kraków, Poland
Bergier T: Department of Environmental Management and Protection, Faculty of Mining Surveying and Environmental Engineering, AGH University of Science and Technology, al. Mickiewicza 30, 30-059 Kraków, Poland [ORCID]
Journal Name
Energies
Volume
14
Issue
16
First Page
5013
Year
2021
Publication Date
2021-08-16
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en14165013, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.33950
This Record
External Link

https://doi.org/10.3390/en14165013
Publisher Version
Download
Files
Apr 24, 2023
Main Article
License
CC BY 4.0
Meta
Record Statistics
Record Views
530
Version History
[v1] (Original Submission)
Apr 24, 2023
 
Verified by curator on
Apr 24, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.33950
 
Record Owner
Auto Uploader for LAPSE
Links to Related Works
Directly Related to This Work
Publisher Version
(0.1 seconds)

[0.1 s]