LAPSE:2023.32678v1
Published Article
LAPSE:2023.32678v1
Optimization of Architectural Form for Thermal Comfort in Naturally Ventilated Gymnasium at Hot and Humid Climate by Orthogonal Experiment
Xiaodan Huang, Qingyuan Zhang, Ineko Tanaka
April 20, 2023
Abstract
As the gymnasiums in subtropical region with hot and humid climate are naturally ventilated during non-competition periods, occupants exercising indoors often feel uncomfortable, especially in summer. In order to provide thermally comfortable and healthy environment for the occupants, the design on architectural form is found to be an effective solution on improving indoor thermal comfort of naturally ventilated gymnasiums. Therefore, a new perspective regarding optimization of naturally ventilated gymnasiums is proposed in the aspect of the architectural form. This paper presents the optimization of architectural form in naturally ventilated gymnasiums in which simulation and orthogonal experiment methods are combined. Through numerical simulation with FlowDesigner software, the significance of architectural form affecting indoor thermal comfort has been given, and the optimal architectural forms of naturally ventilated gymnasium are determined. The results show that the roof insulation type is the most significant factor influencing indoor thermal comfort; thus, it should be considered primarily in optimization. Moreover, the range analysis and variance analysis reveal the rankings of the factors for the gymnasium thermal comfort. In addition, it is demonstrated that the optimal gymnasium model, when compared with the initial gymnasium model, has a satisfactory effect on improving the indoor thermal comfort, as the average value of Predicted Thermal Sensation (PTS) in August decreased from 1.11 (Slightly hot) to 0.86 (Comfortable). This study provides a new insight for the designers in optimizing the architectural form of gymnasiums for achieving the indoor thermal comfort at hot and humid climate.
Keywords
architectural form, gymnasium, hot and humid climate, orthogonal experiment, thermal comfort
Suggested Citation
Huang X, Zhang Q, Tanaka I. Optimization of Architectural Form for Thermal Comfort in Naturally Ventilated Gymnasium at Hot and Humid Climate by Orthogonal Experiment. (2023). LAPSE:2023.32678v1
Author Affiliations
Huang X: School of Art and Design, Guangdong University of Technology, Guangzhou 510090, China; Institute of Urban Innovation, Yokohama National University, Kanagawa 240-8501, Japan
Zhang Q: Institute of Urban Innovation, Yokohama National University, Kanagawa 240-8501, Japan
Tanaka I: Institute of Urban Innovation, Yokohama National University, Kanagawa 240-8501, Japan
Journal Name
Energies
Volume
14
Issue
11
First Page
3228
Year
2021
Publication Date
2021-05-31
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en14113228, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.32678v1
This Record
External Link

https://doi.org/10.3390/en14113228
Publisher Version
Download
Files
Apr 20, 2023
Main Article
License
CC BY 4.0
Meta
Record Statistics
Record Views
243
Version History
[v1] (Original Submission)
Apr 20, 2023
 
Verified by curator on
Apr 20, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.32678v1
 
Record Owner
Auto Uploader for LAPSE
Links to Related Works
Directly Related to This Work
Publisher Version

[1.04 s]