LAPSE:2023.32479
Published Article

LAPSE:2023.32479
Correct Cross-Section of Cable Screen in a Medium Voltage Collector Network with Isolated Neutral of a Wind Power Plant
April 20, 2023
Abstract
The article discusses the selection of cables for power lines connecting wind turbine generators at the wind power plant. The screen cross-section of these cables should be selected considering the value of the screen current at double line-to-earth fault. To calculate this current, the dimensions of the cable should be known. However, these parameters are hidden and cannot be used during designing. Therefore, a highly simplified method is currently used in practice. It is shown that the errors from the highly simplified method are up to 33%. Authors propose a simplified method based on open data of cable manufacturers. The proposed method is compared with simulation results of a common model of cable power line and takes into account self and mutual inductances of the cores and screens. It is shown that the error of the proposed method is smaller than 4.0% for real cable power lines at wind power plants. However, for a long section of cable power line (2.5 km) the error of calculation might increase up to 6.3%. This allows us to use the proposed method for designing. In addition, the authors show how the results of the highly simplified method can be corrected to improve accuracy.
The article discusses the selection of cables for power lines connecting wind turbine generators at the wind power plant. The screen cross-section of these cables should be selected considering the value of the screen current at double line-to-earth fault. To calculate this current, the dimensions of the cable should be known. However, these parameters are hidden and cannot be used during designing. Therefore, a highly simplified method is currently used in practice. It is shown that the errors from the highly simplified method are up to 33%. Authors propose a simplified method based on open data of cable manufacturers. The proposed method is compared with simulation results of a common model of cable power line and takes into account self and mutual inductances of the cores and screens. It is shown that the error of the proposed method is smaller than 4.0% for real cable power lines at wind power plants. However, for a long section of cable power line (2.5 km) the error of calculation might increase up to 6.3%. This allows us to use the proposed method for designing. In addition, the authors show how the results of the highly simplified method can be corrected to improve accuracy.
Record ID
Keywords
cable line, cable screen, double line-to-earth fault current, wind power plant
Subject
Suggested Citation
Al_Issa HA, Qawaqzeh M, Khasawneh A, Buinyi R, Bezruchko V, Miroshnyk O. Correct Cross-Section of Cable Screen in a Medium Voltage Collector Network with Isolated Neutral of a Wind Power Plant. (2023). LAPSE:2023.32479
Author Affiliations
Al_Issa HA: Electrical and Electronics Engineering Department, Al Balqa Applied University, 19117 Al Salt, Jordan [ORCID]
Qawaqzeh M: Electrical and Electronics Engineering Department, Al Balqa Applied University, 19117 Al Salt, Jordan [ORCID]
Khasawneh A: Electrical and Electronics Engineering Department, Al Balqa Applied University, 19117 Al Salt, Jordan [ORCID]
Buinyi R: Department of Power Electrical Engineering, Chernihiv Polytechnic National University, str. Shevchenka, 95, 14035 Chernihiv, Ukraine [ORCID]
Bezruchko V: Department of Power Electrical Engineering, Chernihiv Polytechnic National University, str. Shevchenka, 95, 14035 Chernihiv, Ukraine
Miroshnyk O: Department of Electricity and Energy Management, Kharkiv Petro Vasylenko National Technical University of Agriculture, str. Rizdviana, 19, 61052 Kharkiv, Ukraine [ORCID]
Qawaqzeh M: Electrical and Electronics Engineering Department, Al Balqa Applied University, 19117 Al Salt, Jordan [ORCID]
Khasawneh A: Electrical and Electronics Engineering Department, Al Balqa Applied University, 19117 Al Salt, Jordan [ORCID]
Buinyi R: Department of Power Electrical Engineering, Chernihiv Polytechnic National University, str. Shevchenka, 95, 14035 Chernihiv, Ukraine [ORCID]
Bezruchko V: Department of Power Electrical Engineering, Chernihiv Polytechnic National University, str. Shevchenka, 95, 14035 Chernihiv, Ukraine
Miroshnyk O: Department of Electricity and Energy Management, Kharkiv Petro Vasylenko National Technical University of Agriculture, str. Rizdviana, 19, 61052 Kharkiv, Ukraine [ORCID]
Journal Name
Energies
Volume
14
Issue
11
First Page
3026
Year
2021
Publication Date
2021-05-24
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en14113026, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.32479
This Record
External Link

https://doi.org/10.3390/en14113026
Publisher Version
Download
Meta
Record Statistics
Record Views
171
Version History
[v1] (Original Submission)
Apr 20, 2023
Verified by curator on
Apr 20, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.32479
Record Owner
Auto Uploader for LAPSE
Links to Related Works
[0.81 s]
