LAPSE:2023.29255v1
Published Article

LAPSE:2023.29255v1
Effects of the Wall Properties on the Cooling Efficiency in a Thermosyphon Containing PCM Suspensions
April 13, 2023
Abstract
This study explores the effects of pipe wall properties (thermal conductivity k and wall thickness tw) on the heat transfer performance of a rectangular thermosyphon with a phase change material (PCM) suspension and a geometric configuration (aspect ratio = 1; dimensionless heating section length = 0.8; dimensionless relative elevation between the cooling and the heating sections = 2) that ensures the optimum heat transfer efficiency in the cooling section. The following parameter ranges are studied: the dimensionless loop wall thickness (0 to 0.5), wall-to-fluid thermal conductivity ratio (0.1 to 100), modified Rayleigh number (1010 to 1011), and volumetric fraction of PCM particles (0 to 10%). The results show that appropriate selection of k and tw can lead to improved heat transfer effectiveness in the cooling section of the PCM suspension-containing rectangular thermosyphon.
This study explores the effects of pipe wall properties (thermal conductivity k and wall thickness tw) on the heat transfer performance of a rectangular thermosyphon with a phase change material (PCM) suspension and a geometric configuration (aspect ratio = 1; dimensionless heating section length = 0.8; dimensionless relative elevation between the cooling and the heating sections = 2) that ensures the optimum heat transfer efficiency in the cooling section. The following parameter ranges are studied: the dimensionless loop wall thickness (0 to 0.5), wall-to-fluid thermal conductivity ratio (0.1 to 100), modified Rayleigh number (1010 to 1011), and volumetric fraction of PCM particles (0 to 10%). The results show that appropriate selection of k and tw can lead to improved heat transfer effectiveness in the cooling section of the PCM suspension-containing rectangular thermosyphon.
Record ID
Keywords
heat transfer, latent heat, phase change material, thermosyphon, wall material
Subject
Suggested Citation
Ho CJ, Lin SM, Lai CM. Effects of the Wall Properties on the Cooling Efficiency in a Thermosyphon Containing PCM Suspensions. (2023). LAPSE:2023.29255v1
Author Affiliations
Ho CJ: Department of Mechanical Engineering, National Cheng-Kung University, University Road, Tainan City 701, Taiwan
Lin SM: Department of Mechanical Engineering, National Cheng-Kung University, University Road, Tainan City 701, Taiwan
Lai CM: Department of Civil Engineering, National Cheng-Kung University, University Road, Tainan City 701, Taiwan [ORCID]
Lin SM: Department of Mechanical Engineering, National Cheng-Kung University, University Road, Tainan City 701, Taiwan
Lai CM: Department of Civil Engineering, National Cheng-Kung University, University Road, Tainan City 701, Taiwan [ORCID]
Journal Name
Energies
Volume
14
Issue
3
First Page
572
Year
2021
Publication Date
2021-01-22
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en14030572, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.29255v1
This Record
External Link

https://doi.org/10.3390/en14030572
Publisher Version
Download
Meta
Record Statistics
Record Views
316
Version History
[v1] (Original Submission)
Apr 13, 2023
Verified by curator on
Apr 13, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.29255v1
Record Owner
Auto Uploader for LAPSE
Links to Related Works
(0.08 seconds)
[0.09 s]