Abstract
Geothermal source heat pump (GSHP) systems as renewable energy systems are being more frequently installed as part of the zero-energy building drive. However, in South Korea, where a large amount of heating load can be required, maintaining high system performance by using only a GSHP is difficult owing to the gradual degradation of its thermal performance. The performance of a solar-assisted GSHP system was therefore experimentally analyzed and compared with a GSHP-only system. The results showed that the heating coefficient of performance of the GSHP-only operation was 5.4, while that of the solar-assisted GSHP operation was 7.0. In the case of the GSHP-only system, the maximum temperature of the heat pump water supply on the heat source side was initially 13.1 °C, but this rapidly decreased to 11.4 °C during operation. For the solar-assisted GSHP system, the temperature of the water supply to the heat source side of the heat pump was controlled at 15−20.9 °C, and the power consumption for system operation was reduced by about 20% compared with that for the GSHP-only system. Much higher temperatures could be supplied when solar heat is used instead of ground heat, as solar heat contributes to the performance improvement of the heat pump system.
Geothermal source heat pump (GSHP) systems as renewable energy systems are being more frequently installed as part of the zero-energy building drive. However, in South Korea, where a large amount of heating load can be required, maintaining high system performance by using only a GSHP is difficult owing to the gradual degradation of its thermal performance. The performance of a solar-assisted GSHP system was therefore experimentally analyzed and compared with a GSHP-only system. The results showed that the heating coefficient of performance of the GSHP-only operation was 5.4, while that of the solar-assisted GSHP operation was 7.0. In the case of the GSHP-only system, the maximum temperature of the heat pump water supply on the heat source side was initially 13.1 °C, but this rapidly decreased to 11.4 °C during operation. For the solar-assisted GSHP system, the temperature of the water supply to the heat source side of the heat pump was controlled at 15−20.9 °C, and the power consumption for system operation was reduced by about 20% compared with that for the GSHP-only system. Much higher temperatures could be supplied when solar heat is used instead of ground heat, as solar heat contributes to the performance improvement of the heat pump system.
Record ID
Keywords
coupling, geothermal source heat pump, heating, performance analysis, solar thermal system
Subject
Suggested Citation
Hwang J, Song D, Lee T. The Effect of Coupling Solar Thermal System and Geothermal Heat Pump Systems in Areas with Unbalanced Heating and Cooling Demand. (2023). LAPSE:2023.28718
Author Affiliations
Hwang J: Department of Construction Environmental System Engineering, Sungkyunkwan University, Suwon 16419, Korea; Department of Fire Safety Research, Korea Institute of Civil Engineering and Building Technology, Goyang 10223, Korea
Song D: School of Civil, Architectural Engineering, and Landscape Architecture, Sungkyunkwan University, Suwon 16419, Korea [ORCID]
Lee T: Department of Fire Safety Research, Korea Institute of Civil Engineering and Building Technology, Goyang 10223, Korea
Song D: School of Civil, Architectural Engineering, and Landscape Architecture, Sungkyunkwan University, Suwon 16419, Korea [ORCID]
Lee T: Department of Fire Safety Research, Korea Institute of Civil Engineering and Building Technology, Goyang 10223, Korea
Journal Name
Energies
Volume
14
Issue
1
Article Number
E31
Year
2020
Publication Date
2020-12-23
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en14010031, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.28718
This Record
External Link

https://doi.org/10.3390/en14010031
Publisher Version
Download
Meta
Record Statistics
Record Views
288
Version History
[v1] (Original Submission)
Apr 12, 2023
Verified by curator on
Apr 12, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.28718
Record Owner
Auto Uploader for LAPSE
Links to Related Works
(0.12 seconds)
[0.12 s]