LAPSE:2023.28448v1
Published Article
LAPSE:2023.28448v1
Lightning Performance and Economic Analysis of an Overhead 88 kV Power Delivery Network with Enhanced Protective Systems
Eddie Singh, Innocent E. Davidson, Sindisiwe C. Malanda
April 11, 2023
Abstract
Earthing and protective devices such as line surge arrestors (LSAs) play an important role in areas with high lightning occurrence for overhead HVAC lines’ performance. A lightning stroke of high magnitude can lead to back flash-overs, and the resultant power surge on the phase conductor can cause instigate the line breaker operating to extinguish the power surge. This operation of the protective devices leads to consumer interruptions on the network, a loss of production, and negatively affects the economy. Studies have shown that reducing an earthing system’s values, which itself is costly, may not be sufficient to prevent back flashover and the associated customer production cost loss. A code was developed to determine the possibility of back flashover and the cost of various earthing schemes utilizing the MATLAB software analysis tool. This paper determines the possibility of a back flashover for various combinations of lightning strokes and earthing profiles. Tower Footing Resistances as low as 9.8 Ω can cause back flashover, provided the lightning stroke exceeds 12 kA. Furthermore, the paper presents and discusses an innovative hybrid power line protection scheme, which estimates and considers the high cost associated with establishing an earthing system; it examines the impracticality of re-engineering an earthing scheme for implementation and results obtained by the inclusion of lightning surge arrester’s (LSA). The cost-saving resulting from dips is also established over 25 years for an 88 kV line, and the breakeven point is established. The results showed that the best scenario would be to reduce the tower footing resistance to 29.1 Ω and install 11 LSA per phase.
Keywords
back flashover, breakeven costs, dips, earthing profiles, lightning surge arrester, tower footing resistance
Suggested Citation
Singh E, Davidson IE, Malanda SC. Lightning Performance and Economic Analysis of an Overhead 88 kV Power Delivery Network with Enhanced Protective Systems. (2023). LAPSE:2023.28448v1
Author Affiliations
Singh E: Discipline of Electronic, Electrical, and Computer Engineering, University of KwaZulu-Natal, Durban 4001, South Africa
Davidson IE: Department of Electrical Power Engineering, Durban University of Technology, Durban 4001, South Africa [ORCID]
Malanda SC: Department of Electrical Power Engineering, Durban University of Technology, Durban 4001, South Africa
Journal Name
Energies
Volume
13
Issue
24
Article Number
E6519
Year
2020
Publication Date
2020-12-10
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en13246519, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.28448v1
This Record
External Link

https://doi.org/10.3390/en13246519
Publisher Version
Download
Files
Apr 11, 2023
Main Article
License
CC BY 4.0
Meta
Record Statistics
Record Views
164
Version History
[v1] (Original Submission)
Apr 11, 2023
 
Verified by curator on
Apr 11, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.28448v1
 
Record Owner
Auto Uploader for LAPSE
Links to Related Works
Directly Related to This Work
Publisher Version
(0.28 seconds)