Abstract
Municipal waste biogas plants are an important element of waste treatment and energy policy. In this study, odorant concentrations and emissions were measured together with the air temperature (T) and relative humidity (RH) to confirm the hypothesis that the microclimatic conditions have an important impact on the level of odorant emission at municipal waste biogas plants. A simple correlation analysis was made to evaluate the strength and the direction of the relationship between the odorant concentration and emission and air temperature and relative humidity. The mean volatile organic compound (VOC) and NH3 concentrations vary depending on the stage of the technological line of the analysed municipal waste biogas plants and are in the following ranges, respectively: 0−38.64 ppm and 0−100 ppm. The odorant concentrations and emissions correlated statistically significantly with T primarily influences VOC concentrations and emissions while RH mainly affects NH3 concentrations and emissions. The strongest correlations were noted for the fermentation preparation section and for emissions from roof ventilators depending on the analysed plant. The smallest influence of microclimatic factors was observed at the beginning of the technological line—in the waste storage section and mechanical treatment hall. This is due to the greater impact of the type and quality of waste delivered the plants. The analysis of correlation between individual odorants showed significant relationships between VOCs and NH3 for most stages of the technological line of both biogas plants. In the case of technological sewage pumping stations, a significant relationship was also observed between VOCs and H2S. The obtained results may be helpful in preparing strategies to reduce the odours from waste treatment plants.
Municipal waste biogas plants are an important element of waste treatment and energy policy. In this study, odorant concentrations and emissions were measured together with the air temperature (T) and relative humidity (RH) to confirm the hypothesis that the microclimatic conditions have an important impact on the level of odorant emission at municipal waste biogas plants. A simple correlation analysis was made to evaluate the strength and the direction of the relationship between the odorant concentration and emission and air temperature and relative humidity. The mean volatile organic compound (VOC) and NH3 concentrations vary depending on the stage of the technological line of the analysed municipal waste biogas plants and are in the following ranges, respectively: 0−38.64 ppm and 0−100 ppm. The odorant concentrations and emissions correlated statistically significantly with T primarily influences VOC concentrations and emissions while RH mainly affects NH3 concentrations and emissions. The strongest correlations were noted for the fermentation preparation section and for emissions from roof ventilators depending on the analysed plant. The smallest influence of microclimatic factors was observed at the beginning of the technological line—in the waste storage section and mechanical treatment hall. This is due to the greater impact of the type and quality of waste delivered the plants. The analysis of correlation between individual odorants showed significant relationships between VOCs and NH3 for most stages of the technological line of both biogas plants. In the case of technological sewage pumping stations, a significant relationship was also observed between VOCs and H2S. The obtained results may be helpful in preparing strategies to reduce the odours from waste treatment plants.
Record ID
Keywords
air relative humidity, air temperature, ammonia, biogas plant, correlations, municipal energy, odorant emission, VOCs
Suggested Citation
Wiśniewska M, Kulig A, Lelicińska-Serafin K. The Importance of the Microclimatic Conditions Inside and Outside of Plant Buildings in Odorants Emission at Municipal Waste Biogas Installations. (2023). LAPSE:2023.28077v1
Author Affiliations
Wiśniewska M: Faculty of Building Services, Hydro and Environmental Engineering, Warsaw University of Technology, 20 Nowowiejska Street, 00-653 Warsaw, Poland
Kulig A: Faculty of Building Services, Hydro and Environmental Engineering, Warsaw University of Technology, 20 Nowowiejska Street, 00-653 Warsaw, Poland [ORCID]
Lelicińska-Serafin K: Faculty of Building Services, Hydro and Environmental Engineering, Warsaw University of Technology, 20 Nowowiejska Street, 00-653 Warsaw, Poland
Kulig A: Faculty of Building Services, Hydro and Environmental Engineering, Warsaw University of Technology, 20 Nowowiejska Street, 00-653 Warsaw, Poland [ORCID]
Lelicińska-Serafin K: Faculty of Building Services, Hydro and Environmental Engineering, Warsaw University of Technology, 20 Nowowiejska Street, 00-653 Warsaw, Poland
Journal Name
Energies
Volume
13
Issue
23
Article Number
E6463
Year
2020
Publication Date
2020-12-07
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en13236463, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.28077v1
This Record
External Link

https://doi.org/10.3390/en13236463
Publisher Version
Download
Meta
Record Statistics
Record Views
345
Version History
[v1] (Original Submission)
Apr 11, 2023
Verified by curator on
Apr 11, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.28077v1
Record Owner
Auto Uploader for LAPSE
Links to Related Works
(0.13 seconds)
[0.13 s]