LAPSE:2023.27853
Published Article

LAPSE:2023.27853
Estimation of Energy Efficiency Class Limits for Multi-Family Residential Buildings in Poland
April 11, 2023
Abstract
The need to achieve energy consumption and greenhouse gas emission decreases within the building sector requires the implementation of a supportive legal framework. To fulfil this requirement, a building certification system must be developed that is easily understandable for end users. In Poland, assessments of the energy performance of buildings are based on primary energy indicator verification. However, this parameter is difficult to understand for building owners or for tenants. Therefore, in this study, energy efficiency class limits and a heating indicator for energy needs indicator have been estimated for multi-family buildings in Poland. To achieve this purpose, a reference building was used and 180 calculation variants were developed, which considered the following variables: 3 types of climate data, 4 values of building shape ratios, 3 types of ventilation, 3 thermal transmittance standards and 3 windows area ratios to the external wall. The results showed that the greatest influences on the need for energy used for heating were the type of ventilation used and the local climate. This study shows that the methodology used is adequate for energy efficiency class limits estimations involving multi-family buildings in Poland.
The need to achieve energy consumption and greenhouse gas emission decreases within the building sector requires the implementation of a supportive legal framework. To fulfil this requirement, a building certification system must be developed that is easily understandable for end users. In Poland, assessments of the energy performance of buildings are based on primary energy indicator verification. However, this parameter is difficult to understand for building owners or for tenants. Therefore, in this study, energy efficiency class limits and a heating indicator for energy needs indicator have been estimated for multi-family buildings in Poland. To achieve this purpose, a reference building was used and 180 calculation variants were developed, which considered the following variables: 3 types of climate data, 4 values of building shape ratios, 3 types of ventilation, 3 thermal transmittance standards and 3 windows area ratios to the external wall. The results showed that the greatest influences on the need for energy used for heating were the type of ventilation used and the local climate. This study shows that the methodology used is adequate for energy efficiency class limits estimations involving multi-family buildings in Poland.
Record ID
Keywords
certification, energy efficiency class, energy performance, residential buildings
Subject
Suggested Citation
Kwiatkowski J, Rucińska J. Estimation of Energy Efficiency Class Limits for Multi-Family Residential Buildings in Poland. (2023). LAPSE:2023.27853
Author Affiliations
Kwiatkowski J: District Heating and Natural Gas Systems Division, Faculty of Building Services, Hydro and Environmental Engineering, Warsaw University of Technology, Nowowiejska 20, 00-653 Warsaw, Poland [ORCID]
Rucińska J: Division of Air Conditioning and Heating, Faculty of Building Services, Hydro and Environmental Engineering, Warsaw University of Technology, Nowowiejska 20, 00-653 Warsaw, Poland [ORCID]
Rucińska J: Division of Air Conditioning and Heating, Faculty of Building Services, Hydro and Environmental Engineering, Warsaw University of Technology, Nowowiejska 20, 00-653 Warsaw, Poland [ORCID]
Journal Name
Energies
Volume
13
Issue
23
Article Number
E6234
Year
2020
Publication Date
2020-11-26
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en13236234, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.27853
This Record
External Link

https://doi.org/10.3390/en13236234
Publisher Version
Download
Meta
Record Statistics
Record Views
344
Version History
[v1] (Original Submission)
Apr 11, 2023
Verified by curator on
Apr 11, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.27853
Record Owner
Auto Uploader for LAPSE
Links to Related Works
(0.11 seconds)
[0.11 s]
