Abstract
This research consists of both theoretical and experimental sections presenting a novel scenario for the consumption of hydrogen in the polymer electrolyte membrane fuel cell (PEMFC). In the theory section, a new correction factor called parameter δ is used for the calculation of fuel utilization by introducing concepts of “useful water” and “non-useful water”. The term of “useful water” refers to the state that consumed hydrogen leads to the production of liquid water and external electric current. In the experimental section, the effect of the relative humidity of the cathode side on the performance and power density is investigated by calculating the parameter δ and the modified fuel utilization at 50% and 80% relative humidity. Based on the experimental results, the maximum power density obtained at 50% and 80% relative humidity of the cathode side is about 645 mW/cm2 and 700 mW/cm2, respectively. On the other hand, the maximum value of parameter δ for a value of 50% relative humidity in the cathode side is about 0.88, while for 80% relative humidity it is about 0.72. This means that the modified fuel utilization for 50% relative humidity has a higher value than that for 80%, which is not aligned with previous literature. Therefore, it is necessary to find an optimal range for the relative humidity of the cathode side to achieve the best cell performance in terms of the power generation and fuel consumption as increasing the relative humidity of the cathode itself cannot produce the best result.
Keywords
hydrogen consumption scenarios, modified fuel utilization, PEM fuel cell, useful water
Suggested Citation
Baghban Yousefkhani M, Ghadamian H, Daneshvar K, Alizadeh N, Rincon Troconis BC. Investigation of the Fuel Utilization Factor in PEM Fuel Cell Considering the Effect of Relative Humidity at the Cathode. (2023). LAPSE:2023.27739
Author Affiliations
Baghban Yousefkhani M: Department of Energy, Materials and Energy Research Center (MERC), Tehran 4777-14155, Iran
Ghadamian H: Department of Energy, Materials and Energy Research Center (MERC), Tehran 4777-14155, Iran
Daneshvar K: Department of Mechanical Engineering, University of Texas at San Antonio, San Antonio, TX 78249, USA
Alizadeh N: Department of Natural Resources and Environment, Islamic Azad University, Science and Research Branch (SRBIAU), Tehran 775-14515, Iran
Rincon Troconis BC: Department of Mechanical Engineering, University of Texas at San Antonio, San Antonio, TX 78249, USA [ORCID]
Journal Name
Energies
Volume
13
Issue
22
Article Number
E6117
Year
2020
Publication Date
2020-11-22
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en13226117, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.27739
This Record
External Link

https://doi.org/10.3390/en13226117
Publisher Version
Download
Files
Apr 4, 2023
Main Article
License
CC BY 4.0
Meta
Record Statistics
Record Views
340
Version History
[v1] (Original Submission)
Apr 4, 2023
 
Verified by curator on
Apr 4, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.27739
 
Record Owner
Auto Uploader for LAPSE
Links to Related Works
Directly Related to This Work
Publisher Version
(0.11 seconds)

[0.11 s]