LAPSE:2023.24529v1
Published Article

LAPSE:2023.24529v1
Reflected Traveling Wave Based Single-Ended Fault Location in Distribution Networks
March 28, 2023
Abstract
Traveling wave (TW)-based fault-location methods have been used to determine single-phase-to-ground fault distance in power-distribution networks. The previous approaches detected the arrival time of the initial traveling wave via single ended or multi-terminal measurements. Regarding the multi-branch effect, this paper utilized the reflected waves to obtain multiple arriving times through single ended measurement. Potential fault sections were estimated by searching for the possible traveling wave propagation paths in accordance with the structure of the distribution network. This approach used the entire propagation of a traveling wave measured at a single end without any prerequisite of synchronization, which is a must in multi-terminal measurements. The uniqueness of the fault section was guaranteed by several independent single-ended measurements. Traveling waves obtained in a real 10 kV distribution network were used to determine the fault section, and the results demonstrate the significant effectiveness of the proposed method.
Traveling wave (TW)-based fault-location methods have been used to determine single-phase-to-ground fault distance in power-distribution networks. The previous approaches detected the arrival time of the initial traveling wave via single ended or multi-terminal measurements. Regarding the multi-branch effect, this paper utilized the reflected waves to obtain multiple arriving times through single ended measurement. Potential fault sections were estimated by searching for the possible traveling wave propagation paths in accordance with the structure of the distribution network. This approach used the entire propagation of a traveling wave measured at a single end without any prerequisite of synchronization, which is a must in multi-terminal measurements. The uniqueness of the fault section was guaranteed by several independent single-ended measurements. Traveling waves obtained in a real 10 kV distribution network were used to determine the fault section, and the results demonstrate the significant effectiveness of the proposed method.
Record ID
Keywords
distribution network, fault location, single ended, traveling wave
Subject
Suggested Citation
Shi Y, Zheng T, Yang C. Reflected Traveling Wave Based Single-Ended Fault Location in Distribution Networks. (2023). LAPSE:2023.24529v1
Author Affiliations
Shi Y: Shaanxi Key Laboratory of Smart Grid, School of Electrical Engineering, Xi’an Jiaotong University, Xi’an 710049, China
Zheng T: Shaanxi Key Laboratory of Smart Grid, School of Electrical Engineering, Xi’an Jiaotong University, Xi’an 710049, China [ORCID]
Yang C: Shaanxi Key Laboratory of Smart Grid, School of Electrical Engineering, Xi’an Jiaotong University, Xi’an 710049, China [ORCID]
Zheng T: Shaanxi Key Laboratory of Smart Grid, School of Electrical Engineering, Xi’an Jiaotong University, Xi’an 710049, China [ORCID]
Yang C: Shaanxi Key Laboratory of Smart Grid, School of Electrical Engineering, Xi’an Jiaotong University, Xi’an 710049, China [ORCID]
Journal Name
Energies
Volume
13
Issue
15
Article Number
E3917
Year
2020
Publication Date
2020-07-31
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en13153917, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.24529v1
This Record
External Link

https://doi.org/10.3390/en13153917
Publisher Version
Download
Meta
Record Statistics
Record Views
419
Version History
[v1] (Original Submission)
Mar 28, 2023
Verified by curator on
Mar 28, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.24529v1
Record Owner
Auto Uploader for LAPSE
Links to Related Works
(0.09 seconds)
[0.09 s]
