LAPSE:2023.24516
Published Article

LAPSE:2023.24516
Thermo-Hydraulic Analysis of a Tri-Axial High-Temperature Superconducting Power Cable with Respect to Installation Site Geography
March 28, 2023
Abstract
Various high-temperature superconducting (HTS) power cables are being developed or are ready for commercial operation to help energy suppliers meet the growing power demand in urban areas. Recently, triaxial HTS power cables have been developed by Korea Electric Power Corporation (KEPCO) and LS Cable & System. Further, KEPCO has been planning to install a 2 km long 23 kV/60 MVA triaxial HTS power cable to connect the Munsan and Seonyu substations and increase the stability of the power grid. The HTS power cables should be cooled down to a cryogenic temperature near 77 K. A thermo-hydraulic analysis of the cooling system considering the geographical characteristics of the installation site is essential for long-distance sections. This paper describes the thermo-hydraulic analysis of the triaxial HTS power cable to determine the proper mass flow rates of subcooled liquid nitrogen that meet the operating temperature and pressure of the cable for four configurations of cooling systems: (1) a single cooling system with an external return path, (2) a dual cooling system with an external return path, (3) a single cooling system with an internal return path, and (4) a dual cooling system with internal return path. Since the flow characteristics in a corrugated cable cryostat differ significantly from those in a typical annular tube, a computational fluid dynamics (CFD) analysis was conducted to estimate the pressure drop along the cable cryostat. With the CFD analysis and given heat loads in the cable, the temperature and the pressure variations along the cable were calculated and their pros and cons were compared for each configuration of the cooling system. This thermo-hydraulic analysis will be referenced in the actual installation of the HTS power cable between the Munsan and Seonyu substations.
Various high-temperature superconducting (HTS) power cables are being developed or are ready for commercial operation to help energy suppliers meet the growing power demand in urban areas. Recently, triaxial HTS power cables have been developed by Korea Electric Power Corporation (KEPCO) and LS Cable & System. Further, KEPCO has been planning to install a 2 km long 23 kV/60 MVA triaxial HTS power cable to connect the Munsan and Seonyu substations and increase the stability of the power grid. The HTS power cables should be cooled down to a cryogenic temperature near 77 K. A thermo-hydraulic analysis of the cooling system considering the geographical characteristics of the installation site is essential for long-distance sections. This paper describes the thermo-hydraulic analysis of the triaxial HTS power cable to determine the proper mass flow rates of subcooled liquid nitrogen that meet the operating temperature and pressure of the cable for four configurations of cooling systems: (1) a single cooling system with an external return path, (2) a dual cooling system with an external return path, (3) a single cooling system with an internal return path, and (4) a dual cooling system with internal return path. Since the flow characteristics in a corrugated cable cryostat differ significantly from those in a typical annular tube, a computational fluid dynamics (CFD) analysis was conducted to estimate the pressure drop along the cable cryostat. With the CFD analysis and given heat loads in the cable, the temperature and the pressure variations along the cable were calculated and their pros and cons were compared for each configuration of the cooling system. This thermo-hydraulic analysis will be referenced in the actual installation of the HTS power cable between the Munsan and Seonyu substations.
Record ID
Keywords
heat loss, high-temperature superconductor, HTS power cable, pressure drop, thermo-hydraulic analysis
Subject
Suggested Citation
Choi Y, Kim D, Lee C, Won D, Yoo J, Yang H, Kim S. Thermo-Hydraulic Analysis of a Tri-Axial High-Temperature Superconducting Power Cable with Respect to Installation Site Geography. (2023). LAPSE:2023.24516
Author Affiliations
Choi Y: Department of Mechanical Engineering, Changwon National University, Changwon 641-773, Korea
Kim D: Department of Mechanical Engineering, Changwon National University, Changwon 641-773, Korea
Lee C: Department of Mechanical Engineering, Changwon National University, Changwon 641-773, Korea
Won D: Korea Electric Power Corporation Research Institute, Daejeon 34056, Korea
Yoo J: Korea Electric Power Corporation Research Institute, Daejeon 34056, Korea
Yang H: Korea Electric Power Corporation Research Institute, Daejeon 34056, Korea
Kim S: Department of Mechanical Engineering, Changwon National University, Changwon 641-773, Korea [ORCID]
Kim D: Department of Mechanical Engineering, Changwon National University, Changwon 641-773, Korea
Lee C: Department of Mechanical Engineering, Changwon National University, Changwon 641-773, Korea
Won D: Korea Electric Power Corporation Research Institute, Daejeon 34056, Korea
Yoo J: Korea Electric Power Corporation Research Institute, Daejeon 34056, Korea
Yang H: Korea Electric Power Corporation Research Institute, Daejeon 34056, Korea
Kim S: Department of Mechanical Engineering, Changwon National University, Changwon 641-773, Korea [ORCID]
Journal Name
Energies
Volume
13
Issue
15
Article Number
E3898
Year
2020
Publication Date
2020-07-30
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en13153898, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.24516
This Record
External Link

https://doi.org/10.3390/en13153898
Publisher Version
Download
Meta
Record Statistics
Record Views
306
Version History
[v1] (Original Submission)
Mar 28, 2023
Verified by curator on
Mar 28, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.24516
Record Owner
Auto Uploader for LAPSE
Links to Related Works
