Abstract
This paper describes a correlation of partial discharge phase-resolved patterns with an optical imaging performed in a non-uniform electric field configuration. The influence of different dielectric barrier materials, placed on the plane electrode, on the discharge propagation and surface landing was investigated. The investigations were focused on the corona at positive polarity of AC high voltage. It was found that the initial positive corona stage is similar for all cases whereas the discharge propagation and surface landing strongly depends on the barrier material properties. The observed streamer discharge modes have been described by the geometrical measures such as stem length, stretch of a discharge profile on the dielectric barrier surface and an hemispherical envelope of discharge filaments. Since various dielectrics reveal different properties of charge accumulation and surface neutralization, the charge memory effect may be visible and can be related to the ability to create and sustain of additional electric field component. It may refer to subsequent discharges as well as to conditions faced at the voltage polarity reversal. The correspondence between different forms of phase-resolved patterns have been associated with the modes of streamer discharges observed by optical imaging. Presented methodology poses huge potential for both scientific investigations on underlying discharge phenomena as well as on the application in future diagnostic systems of HV insulation.
This paper describes a correlation of partial discharge phase-resolved patterns with an optical imaging performed in a non-uniform electric field configuration. The influence of different dielectric barrier materials, placed on the plane electrode, on the discharge propagation and surface landing was investigated. The investigations were focused on the corona at positive polarity of AC high voltage. It was found that the initial positive corona stage is similar for all cases whereas the discharge propagation and surface landing strongly depends on the barrier material properties. The observed streamer discharge modes have been described by the geometrical measures such as stem length, stretch of a discharge profile on the dielectric barrier surface and an hemispherical envelope of discharge filaments. Since various dielectrics reveal different properties of charge accumulation and surface neutralization, the charge memory effect may be visible and can be related to the ability to create and sustain of additional electric field component. It may refer to subsequent discharges as well as to conditions faced at the voltage polarity reversal. The correspondence between different forms of phase-resolved patterns have been associated with the modes of streamer discharges observed by optical imaging. Presented methodology poses huge potential for both scientific investigations on underlying discharge phenomena as well as on the application in future diagnostic systems of HV insulation.
Record ID
Keywords
corona discharges, imaging, non-uniform electric field, partial discharges
Subject
Suggested Citation
Florkowski M, Krześniak D, Kuniewski M, Zydroń P. Partial Discharge Imaging Correlated with Phase-Resolved Patterns in Non-Uniform Electric Fields with Various Dielectric Barrier Materials. (2023). LAPSE:2023.23292
Author Affiliations
Florkowski M: Department of Electrical and Power Engineering, AGH University of Science and Technology, al. Mickiewicza 30, 30-059 Kraków, Poland [ORCID]
Krześniak D: ABB Corporate Technology Center, ul. Starowiślna 13a, 31-038 Kraków, Poland
Kuniewski M: Department of Electrical and Power Engineering, AGH University of Science and Technology, al. Mickiewicza 30, 30-059 Kraków, Poland [ORCID]
Zydroń P: Department of Electrical and Power Engineering, AGH University of Science and Technology, al. Mickiewicza 30, 30-059 Kraków, Poland [ORCID]
Krześniak D: ABB Corporate Technology Center, ul. Starowiślna 13a, 31-038 Kraków, Poland
Kuniewski M: Department of Electrical and Power Engineering, AGH University of Science and Technology, al. Mickiewicza 30, 30-059 Kraków, Poland [ORCID]
Zydroń P: Department of Electrical and Power Engineering, AGH University of Science and Technology, al. Mickiewicza 30, 30-059 Kraków, Poland [ORCID]
Journal Name
Energies
Volume
13
Issue
11
Article Number
E2676
Year
2020
Publication Date
2020-05-26
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en13112676, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.23292
This Record
External Link

https://doi.org/10.3390/en13112676
Publisher Version
Download
Meta
Record Statistics
Record Views
208
Version History
[v1] (Original Submission)
Mar 27, 2023
Verified by curator on
Mar 27, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.23292
Record Owner
Auto Uploader for LAPSE
Links to Related Works