Abstract
Insulators comprise only 5% of the capital cost of transmission lines; they are accountable for 70% of line interruptions and 50% of maintenance costs of transmission lines. Major transmission lines situated in different parts of the world were mostly all constructed 30 years ago. These lines have either completed or are approaching the active life at 30 years. It is not possible to replace all insulators at a time in any utility. From a standpoint of consistency, it is quite important to locate insulators that require replacement prior to the occurrence of failure. Recalling these issues, a replacement strategy was modeled on insulator samples, operated at 154 kV, mechanical and electrical rating (M+E) 25,000 lbs and within the 10−50 years (Y) age group, collected in bulk for laboratory evaluation, based on the probability of mechanical failure (P(F)) of insulators. For conducting these studies, tensile load test such as combined electrical and mechanical failing load test was performed on selected 30 new and aged porcelain insulator samples from bulk to access recent condition. It was observed that insulators under service for 50 years manifested a decrease of 89.3% in quality factor (K), as compared to insulators within 10 years of service. A micro-structural study was carried out by using an optical microscope (OM) and a scanning electron microscope (SEM) for the further confirmation of previous evaluations. P(F) was derived by implementing Weibull distribution on the experimental observations. It was observed that insulators with an age of 50 years depicted a 2.7% increase in P(F), as compared to insulators with an age of 10 years. This article discussed a strategy for accessing the recent condition of new, aged bulk samples and the criteria of the replacement of the insulator string based on P(F).
Insulators comprise only 5% of the capital cost of transmission lines; they are accountable for 70% of line interruptions and 50% of maintenance costs of transmission lines. Major transmission lines situated in different parts of the world were mostly all constructed 30 years ago. These lines have either completed or are approaching the active life at 30 years. It is not possible to replace all insulators at a time in any utility. From a standpoint of consistency, it is quite important to locate insulators that require replacement prior to the occurrence of failure. Recalling these issues, a replacement strategy was modeled on insulator samples, operated at 154 kV, mechanical and electrical rating (M+E) 25,000 lbs and within the 10−50 years (Y) age group, collected in bulk for laboratory evaluation, based on the probability of mechanical failure (P(F)) of insulators. For conducting these studies, tensile load test such as combined electrical and mechanical failing load test was performed on selected 30 new and aged porcelain insulator samples from bulk to access recent condition. It was observed that insulators under service for 50 years manifested a decrease of 89.3% in quality factor (K), as compared to insulators within 10 years of service. A micro-structural study was carried out by using an optical microscope (OM) and a scanning electron microscope (SEM) for the further confirmation of previous evaluations. P(F) was derived by implementing Weibull distribution on the experimental observations. It was observed that insulators with an age of 50 years depicted a 2.7% increase in P(F), as compared to insulators with an age of 10 years. This article discussed a strategy for accessing the recent condition of new, aged bulk samples and the criteria of the replacement of the insulator string based on P(F).
Record ID
Keywords
microstructural study, probability of failure, replacement strategy, tensile load test, Weibull distribution
Subject
Suggested Citation
Sanyal S, Kim T, Seok CS, Yi J, Koo JB, Son JA, Choi IH. Replacement Strategy of Insulators Established by Probability of Failure. (2023). LAPSE:2023.22908
Author Affiliations
Sanyal S: College of Information and Communication Engineering, Sungkyunkwan University, Suwon 16419, Gyeonggi-Do, Korea
Kim T: College of Information and Communication Engineering, Sungkyunkwan University, Suwon 16419, Gyeonggi-Do, Korea [ORCID]
Seok CS: College of Information and Communication Engineering, Sungkyunkwan University, Suwon 16419, Gyeonggi-Do, Korea
Yi J: College of Information and Communication Engineering, Sungkyunkwan University, Suwon 16419, Gyeonggi-Do, Korea
Koo JB: 2KEPCO Research Institute, Daejeon 34056, Korea
Son JA: 2KEPCO Research Institute, Daejeon 34056, Korea
Choi IH: 2KEPCO Research Institute, Daejeon 34056, Korea
Kim T: College of Information and Communication Engineering, Sungkyunkwan University, Suwon 16419, Gyeonggi-Do, Korea [ORCID]
Seok CS: College of Information and Communication Engineering, Sungkyunkwan University, Suwon 16419, Gyeonggi-Do, Korea
Yi J: College of Information and Communication Engineering, Sungkyunkwan University, Suwon 16419, Gyeonggi-Do, Korea
Koo JB: 2KEPCO Research Institute, Daejeon 34056, Korea
Son JA: 2KEPCO Research Institute, Daejeon 34056, Korea
Choi IH: 2KEPCO Research Institute, Daejeon 34056, Korea
Journal Name
Energies
Volume
13
Issue
8
Article Number
E2043
Year
2020
Publication Date
2020-04-20
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en13082043, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.22908
This Record
External Link

https://doi.org/10.3390/en13082043
Publisher Version
Download
Meta
Record Statistics
Record Views
339
Version History
[v1] (Original Submission)
Mar 24, 2023
Verified by curator on
Mar 24, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.22908
Record Owner
Auto Uploader for LAPSE
Links to Related Works
(0.11 seconds)
[0.11 s]