Abstract
The cost of the PV energy reduction is still required to increase the penetration level of PV systems in the energy market. The reliability of PV inverters is one of the important aspects to be enhanced in order to reduce the cost of PV energy, since it is closely related to the maintenance cost and the annual energy production. In this paper, the lifetime of NPC and T-type inverters, which are three-level inverter topologies that are widely used for PV systems, are comparatively evaluated with a 30 kW grid-connected PV system. It is performed by focusing on power devices since the power electronic components of both converters are the same except for the power devices. Therefore, this result can represent the comparison of the reliability performance of the NPC and T-type inverters. The power loss and temperature distributions of power devices are analyzed and their efficiencies are compared at different power levels with different switching frequencies. The lifetimes of the reliability-critical power devices in the NPC and T-type inverters are estimated, respectively with a one-year mission profile of the PV system, and the results are compared.
The cost of the PV energy reduction is still required to increase the penetration level of PV systems in the energy market. The reliability of PV inverters is one of the important aspects to be enhanced in order to reduce the cost of PV energy, since it is closely related to the maintenance cost and the annual energy production. In this paper, the lifetime of NPC and T-type inverters, which are three-level inverter topologies that are widely used for PV systems, are comparatively evaluated with a 30 kW grid-connected PV system. It is performed by focusing on power devices since the power electronic components of both converters are the same except for the power devices. Therefore, this result can represent the comparison of the reliability performance of the NPC and T-type inverters. The power loss and temperature distributions of power devices are analyzed and their efficiencies are compared at different power levels with different switching frequencies. The lifetimes of the reliability-critical power devices in the NPC and T-type inverters are estimated, respectively with a one-year mission profile of the PV system, and the results are compared.
Record ID
Keywords
IGBT module, lifetime, power device, PV inverter, reliability, three-level inverter
Subject
Suggested Citation
Choi UM, Lee JS. Comparative Evaluation of Lifetime of Three-Level Inverters in Grid-Connected Photovoltaic Systems. (2023). LAPSE:2023.21998
Author Affiliations
Choi UM: Department of Electronic and IT Media Engineering, Seoul National University of Science and Technology, Seoul 01811, Korea
Lee JS: School of Electronics and Electrical Engineering, Dankook University, Yongin-si 16890, Korea [ORCID]
Lee JS: School of Electronics and Electrical Engineering, Dankook University, Yongin-si 16890, Korea [ORCID]
Journal Name
Energies
Volume
13
Issue
5
Article Number
E1227
Year
2020
Publication Date
2020-03-06
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en13051227, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.21998
This Record
External Link

https://doi.org/10.3390/en13051227
Publisher Version
Download
Meta
Record Statistics
Record Views
142
Version History
[v1] (Original Submission)
Mar 23, 2023
Verified by curator on
Mar 23, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.21998
Record Owner
Auto Uploader for LAPSE
Links to Related Works