Integration of Stand-Alone Controlled Active Power Filters in Harmonic Power Flow of Radial Distribution Networks
March 20, 2023
Abstract
Utilization of active power filters (APFs) is the most efficient method to reduce harmonic pollution in distribution networks. Previous approaches utilized APFs in integrated control schemes based on broad data-gathering systems. Since a broad data-gathering system is not available in most practical distribution networks, previously proposed approaches may not readily be implemented. This paper presents the utilization of stand-alone controlled APFs (SACAPFs) in radial distribution networks. Utilizing APFs with a stand-alone control system decreases implementation costs and complexity by making them autonomous and independent of integrated control systems, which are complicated and expensive in practical applications. In this paper, a single SACAPF is modeled as a dependent current source where its injection current is equal in amplitude but opposite in phase compared to the harmonic content of the current passing through the point of common coupling (reference current). Due to the presence of both linear and nonlinear loads in the distribution network, the reference current changes after injection by SACAPF, so it is necessary to modify the injection current until reaching a constant value in the reference current. This is considered via an iterative procedure in the modeling scheme. Operation of multiple SACAPFs is handled using a backward procedure based on a priority list. Simulation results on an IEEE 18-bus test system show the proper operation of the stand-alone control systems for both single and multiple SACAPF implementation. Furthermore, optimal allocation of the proposed SACAPFs is performed in an IEEE 33-bus test network and a 9-bus test network, and the results are discussed and compared with the allocation of integrated control system APFs.
Utilization of active power filters (APFs) is the most efficient method to reduce harmonic pollution in distribution networks. Previous approaches utilized APFs in integrated control schemes based on broad data-gathering systems. Since a broad data-gathering system is not available in most practical distribution networks, previously proposed approaches may not readily be implemented. This paper presents the utilization of stand-alone controlled APFs (SACAPFs) in radial distribution networks. Utilizing APFs with a stand-alone control system decreases implementation costs and complexity by making them autonomous and independent of integrated control systems, which are complicated and expensive in practical applications. In this paper, a single SACAPF is modeled as a dependent current source where its injection current is equal in amplitude but opposite in phase compared to the harmonic content of the current passing through the point of common coupling (reference current). Due to the presence of both linear and nonlinear loads in the distribution network, the reference current changes after injection by SACAPF, so it is necessary to modify the injection current until reaching a constant value in the reference current. This is considered via an iterative procedure in the modeling scheme. Operation of multiple SACAPFs is handled using a backward procedure based on a priority list. Simulation results on an IEEE 18-bus test system show the proper operation of the stand-alone control systems for both single and multiple SACAPF implementation. Furthermore, optimal allocation of the proposed SACAPFs is performed in an IEEE 33-bus test network and a 9-bus test network, and the results are discussed and compared with the allocation of integrated control system APFs.
Record ID
Keywords
active power filter, electrical distribution network, harmonic pollution, stand-alone control system
Subject
Suggested Citation
Rezapour H, Amini M, Falaghi H, Lopes AM. Integration of Stand-Alone Controlled Active Power Filters in Harmonic Power Flow of Radial Distribution Networks. (2023). LAPSE:2023.20528
Author Affiliations
Rezapour H: Electrical Engineering Department, Iran University of Science and Technology (IUST), Tehran 16846-13114, Iran; Faculty of Electrical and Computer Engineering, University of Birjand, Birjand 97174-34765, Iran
Amini M: Electrical Engineering Department, Iran University of Science and Technology (IUST), Tehran 16846-13114, Iran
Falaghi H: Faculty of Electrical and Computer Engineering, University of Birjand, Birjand 97174-34765, Iran
Lopes AM: LAETA/INEGI, Faculty of Engineering, University of Porto, 4200-465 Porto, Portugal [ORCID]
Amini M: Electrical Engineering Department, Iran University of Science and Technology (IUST), Tehran 16846-13114, Iran
Falaghi H: Faculty of Electrical and Computer Engineering, University of Birjand, Birjand 97174-34765, Iran
Lopes AM: LAETA/INEGI, Faculty of Engineering, University of Porto, 4200-465 Porto, Portugal [ORCID]
Journal Name
Energies
Volume
16
Issue
5
First Page
2463
Year
2023
Publication Date
2023-03-04
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en16052463, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.20528
This Record
External Link

https://doi.org/10.3390/en16052463
Publisher Version
Download
Meta
Record Statistics
Record Views
397
Version History
[v1] (Original Submission)
Mar 20, 2023
Verified by curator on
Mar 20, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.20528
Record Owner
Auto Uploader for LAPSE
Links to Related Works
(0.07 seconds)
[0.08 s]