Abstract
Based on the experimental studies, the process of ground regeneration around the borehole loaded with brine-water heat pumps working exclusively for heating purposes in the period of four consecutive heating seasons in a cold climate was presented. The research was conducted in north-eastern Poland. The aim of the work is to verify the phenomenon of thermal ground regeneration in the period between heating seasons on the basis of the recorded data and to check whether the ground is able to regenerate itself and at what rate. It was noticed that the ground does not fully regenerate, especially during heating seasons with lower temperatures. In the analyzed period, from 22 September 2016 to 12 October 2020, the ground probably cooled irreversibly by 1.5 °C. In order to illustrate and evaluate the speed of changes in the ground, the one’s profile with an undisturbed temperature field was presented for each month of the year. The presented results can be a very important source of information for the analysis of geothermal conditions occurring in the ground. They can be used to verify mathematical models and conduct long-term simulations that allow us to see the complexity of the processes taking place in the ground.
Based on the experimental studies, the process of ground regeneration around the borehole loaded with brine-water heat pumps working exclusively for heating purposes in the period of four consecutive heating seasons in a cold climate was presented. The research was conducted in north-eastern Poland. The aim of the work is to verify the phenomenon of thermal ground regeneration in the period between heating seasons on the basis of the recorded data and to check whether the ground is able to regenerate itself and at what rate. It was noticed that the ground does not fully regenerate, especially during heating seasons with lower temperatures. In the analyzed period, from 22 September 2016 to 12 October 2020, the ground probably cooled irreversibly by 1.5 °C. In order to illustrate and evaluate the speed of changes in the ground, the one’s profile with an undisturbed temperature field was presented for each month of the year. The presented results can be a very important source of information for the analysis of geothermal conditions occurring in the ground. They can be used to verify mathematical models and conduct long-term simulations that allow us to see the complexity of the processes taking place in the ground.
Record ID
Keywords
BHE, borehole heat exchanger, extracted energy, ground thermal conductivity, ground-source heat pump, regeneration, thermal performance
Subject
Suggested Citation
Piotrowska-Woroniak J. Assessment of Ground Regeneration around Borehole Heat Exchangers between Heating Seasons in Cold Climates: A Case Study in Bialystok (NE, Poland). (2023). LAPSE:2023.20081
Author Affiliations
Piotrowska-Woroniak J: HVAC Department, Bialystok University of Technology, Wiejska 45E, 15-351 Bialystok, Poland [ORCID]
Journal Name
Energies
Volume
14
Issue
16
First Page
4793
Year
2021
Publication Date
2021-08-06
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en14164793, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.20081
This Record
External Link

https://doi.org/10.3390/en14164793
Publisher Version
Download
Meta
Record Statistics
Record Views
292
Version History
[v1] (Original Submission)
Mar 10, 2023
Verified by curator on
Mar 10, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.20081
Record Owner
Auto Uploader for LAPSE
Links to Related Works
(0.08 seconds)
[0.08 s]