LAPSE:2023.19988
Published Article

LAPSE:2023.19988
Data-Driven Virtual Inertia Control Method of Doubly Fed Wind Turbine
March 10, 2023
Abstract
This paper presents a data-driven virtual inertia control method for doubly fed induction generator (DFIG)-based wind turbine to provide inertia support in the presence of frequency events. The Markov parameters of the system are first obtained by monitoring the grid frequency and system operation state. Then, a data-driven state observer is developed to evaluate the state vector of the optimal controller. Furthermore, the optimal controller of the inertia emulation system is developed through the closed solution of the differential Riccati equation. Moreover, a differential Riccati equation with self-correction capability is developed to enhance the anti-noise ability to reject noise interference in frequency measurement process. Finally, the simulation verification was performed in Matlab/Simulink to validate the effectiveness of the proposed control strategy. Simulation results showed that the proposed virtual inertia controller can adaptively tune control parameters online to provide transient inertia supports for the power grid by releasing the kinetic energy, so as to improve the robustness and anti-interference ability of the control system of the wind power system.
This paper presents a data-driven virtual inertia control method for doubly fed induction generator (DFIG)-based wind turbine to provide inertia support in the presence of frequency events. The Markov parameters of the system are first obtained by monitoring the grid frequency and system operation state. Then, a data-driven state observer is developed to evaluate the state vector of the optimal controller. Furthermore, the optimal controller of the inertia emulation system is developed through the closed solution of the differential Riccati equation. Moreover, a differential Riccati equation with self-correction capability is developed to enhance the anti-noise ability to reject noise interference in frequency measurement process. Finally, the simulation verification was performed in Matlab/Simulink to validate the effectiveness of the proposed control strategy. Simulation results showed that the proposed virtual inertia controller can adaptively tune control parameters online to provide transient inertia supports for the power grid by releasing the kinetic energy, so as to improve the robustness and anti-interference ability of the control system of the wind power system.
Record ID
Keywords
data-driven control, DFIG, Markov parameters, optimal feedback controller, self-correction, virtual inertia
Subject
Suggested Citation
Li T, Wang L, Wang Y, Liu G, Zhu Z, Zhang Y, Zhao L, Ji Z. Data-Driven Virtual Inertia Control Method of Doubly Fed Wind Turbine. (2023). LAPSE:2023.19988
Author Affiliations
Li T: School of Electronic Information, Jiangsu University of Science and Technology, Zhenjiang 212003, China; School of Electrical Information Engineering, Jiangsu University, Zhenjiang 212213, China; Shandong Driving Thunder Technology Development Co., Ltd.,
Wang L: School of Electronic Information, Jiangsu University of Science and Technology, Zhenjiang 212003, China
Wang Y: Department of Energy Technology, Aalborg University, 9220 Aalborg, Denmark
Liu G: School of Electrical Information Engineering, Jiangsu University, Zhenjiang 212213, China
Zhu Z: School of Electronic Information, Jiangsu University of Science and Technology, Zhenjiang 212003, China
Zhang Y: School of Electronic Information, Jiangsu University of Science and Technology, Zhenjiang 212003, China
Zhao L: Shandong Water Polytechnic, Department of Mechanical and Electrical Engineering, Rizhao 276826, China
Ji Z: School of Internet of Things Engineering, Jiangnan University, Wuxi 214112, China
Wang L: School of Electronic Information, Jiangsu University of Science and Technology, Zhenjiang 212003, China
Wang Y: Department of Energy Technology, Aalborg University, 9220 Aalborg, Denmark
Liu G: School of Electrical Information Engineering, Jiangsu University, Zhenjiang 212213, China
Zhu Z: School of Electronic Information, Jiangsu University of Science and Technology, Zhenjiang 212003, China
Zhang Y: School of Electronic Information, Jiangsu University of Science and Technology, Zhenjiang 212003, China
Zhao L: Shandong Water Polytechnic, Department of Mechanical and Electrical Engineering, Rizhao 276826, China
Ji Z: School of Internet of Things Engineering, Jiangnan University, Wuxi 214112, China
Journal Name
Energies
Volume
14
Issue
17
First Page
5572
Year
2021
Publication Date
2021-09-06
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en14175572, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.19988
This Record
External Link

https://doi.org/10.3390/en14175572
Publisher Version
Download
Meta
Record Statistics
Record Views
287
Version History
[v1] (Original Submission)
Mar 10, 2023
Verified by curator on
Mar 10, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.19988
Record Owner
Auto Uploader for LAPSE
Links to Related Works
(0.08 seconds)
[0.08 s]
