Model for 400 kV Transmission Line Power Loss Assessment Using the PMU Measurements
March 9, 2023
Abstract
This paper presents an advanced model for monitoring losses on a 400 kV over-head transmission line (OHL) that can be used for measured data verification and loss assessment. Technical losses are unavoidable physical effects of energy transmission and can be reduced to acceptable levels, with a major share of technical losses on transmission lines being Joule losses. However, at 400 kV voltage levels, the influence of the electrical corona discharge effect and current leakage can have significant impact on power loss. This is especially visible in poor weather conditions, such as the appearance of fog, rain and snow. Therefore, loss monitoring is incorporated into exiting business process to provide transmission system operators (TSO) with the measure of losses and the accurate characterization of measured data. This paper presents an advanced model for loss characterization and assessment that uses phasor measurement unit (PMU) measurements and combines them with end-customer measurements. PMU measurements from the algorithm of differential protection are used to detect differential currents and angles, and this paper proposes further usage of these data for determining the corona losses. The collected data are further processed and used to calculate the amount of corona losses and provide accurate loss assessment and estimation. In each step of the model, cross verification of the measured and calculated data is performed in order to finally provide more accurate loss assessment which is incorporated into the current data acquisition and monitoring systems.
This paper presents an advanced model for monitoring losses on a 400 kV over-head transmission line (OHL) that can be used for measured data verification and loss assessment. Technical losses are unavoidable physical effects of energy transmission and can be reduced to acceptable levels, with a major share of technical losses on transmission lines being Joule losses. However, at 400 kV voltage levels, the influence of the electrical corona discharge effect and current leakage can have significant impact on power loss. This is especially visible in poor weather conditions, such as the appearance of fog, rain and snow. Therefore, loss monitoring is incorporated into exiting business process to provide transmission system operators (TSO) with the measure of losses and the accurate characterization of measured data. This paper presents an advanced model for loss characterization and assessment that uses phasor measurement unit (PMU) measurements and combines them with end-customer measurements. PMU measurements from the algorithm of differential protection are used to detect differential currents and angles, and this paper proposes further usage of these data for determining the corona losses. The collected data are further processed and used to calculate the amount of corona losses and provide accurate loss assessment and estimation. In each step of the model, cross verification of the measured and calculated data is performed in order to finally provide more accurate loss assessment which is incorporated into the current data acquisition and monitoring systems.
Record ID
Keywords
corona losses, metering data, synchrophasor (PMU) measurements, transmission line losses
Subject
Suggested Citation
Pavičić I, Holjevac N, Ivanković I, Brnobić D. Model for 400 kV Transmission Line Power Loss Assessment Using the PMU Measurements. (2023). LAPSE:2023.19977v1
Author Affiliations
Pavičić I: Croatian Transmission System Operator, HOPS, 10000 Zagreb, Croatia
Holjevac N: Faculty of Electrical Engineering and Computing, University of Zagreb, 10000 Zagreb, Croatia [ORCID]
Ivanković I: Croatian Transmission System Operator, HOPS, 10000 Zagreb, Croatia [ORCID]
Brnobić D: Studio Elektronike Rijeka Ltd., 51000 Rijeka, Croatia
Holjevac N: Faculty of Electrical Engineering and Computing, University of Zagreb, 10000 Zagreb, Croatia [ORCID]
Ivanković I: Croatian Transmission System Operator, HOPS, 10000 Zagreb, Croatia [ORCID]
Brnobić D: Studio Elektronike Rijeka Ltd., 51000 Rijeka, Croatia
Journal Name
Energies
Volume
14
Issue
17
First Page
5562
Year
2021
Publication Date
2021-09-06
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en14175562, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.19977v1
This Record
External Link

https://doi.org/10.3390/en14175562
Publisher Version
Download
Meta
Record Statistics
Record Views
320
Version History
[v1] (Original Submission)
Mar 9, 2023
Verified by curator on
Mar 9, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.19977v1
Record Owner
Auto Uploader for LAPSE
Links to Related Works
(0.09 seconds)
[0.1 s]