This paper presents the results of an analysis using the direct current internal resistance (DCIR) method on a nickel-cobalt-manganese oxide (NCM)-based battery with a nominal capacity of 55.6 Ah. The accelerated degradation test was performed on V0G, V1G, and V2G patterns, representing existing simple power supply, smart charging control, and bi-directional charge/discharge control, respectively. We assumed V0G, V1G, and V2G patterns and conducted charging and discharging experiments according to the set conditions. According to the pattern repetition, changes in the internal resistance of DCIR and AC-impedance were analyzed and battery deterioration was diagnosed. By comparing DCIR and AC-impedance, we confirmed that the changes in internal resistance has a similar trend. In particular, we propose a new DCIR analysis method in the “stop-operation” part rather than the traditional DCIR method. In the case of traditional DCIR method, time is required for the battery to stabilize. However, the newly proposed DCIR analysis method has the advantage of diagnosing the deterioration of the battery during system operation by analyzing the internal resistance without the stabilization time of the battery.
This paper presents the results of an analysis using the direct current internal resistance (DCIR) method on a nickel-cobalt-manganese oxide (NCM)-based battery with a nominal capacity of 55.6 Ah. The accelerated degradation test was performed on V0G, V1G, and V2G patterns, representing existing simple power supply, smart charging control, and bi-directional charge/discharge control, respectively. We assumed V0G, V1G, and V2G patterns and conducted charging and discharging experiments according to the set conditions. According to the pattern repetition, changes in the internal resistance of DCIR and AC-impedance were analyzed and battery deterioration was diagnosed. By comparing DCIR and AC-impedance, we confirmed that the changes in internal resistance has a similar trend. In particular, we propose a new DCIR analysis method in the “stop-operation” part rather than the traditional DCIR method. In the case of traditional DCIR method, time is required for the battery to stabilize. However, the newly proposed DCIR analysis method has the advantage of diagnosing the deterioration of the battery during system operation by analyzing the internal resistance without the stabilization time of the battery.
Record ID
Keywords
direct current internal resistance (DCIR), electric vehicle (EV), energy storage system (ESS), galvanostatic intermittent titration technique (GITT), V2G
Subject
Suggested Citation
Lim J, Lee SE, Park KY, Kim HS, Choi JH. VxG Pattern-Based Analysis and Battery Deterioration Diagnosis. (2023). LAPSE:2023.19845v1
Author Affiliations
Lim J: New and Renewable Energy Laboratory, KEPCO Research Institute, Korea Electric Power Corporation, 105 Munji-ro Yuseong-gu, Daejeon 34056, Korea
Lee SE: New and Renewable Energy Laboratory, KEPCO Research Institute, Korea Electric Power Corporation, 105 Munji-ro Yuseong-gu, Daejeon 34056, Korea
Park KY: New and Renewable Energy Laboratory, KEPCO Research Institute, Korea Electric Power Corporation, 105 Munji-ro Yuseong-gu, Daejeon 34056, Korea
Kim HS: New and Renewable Energy Laboratory, KEPCO Research Institute, Korea Electric Power Corporation, 105 Munji-ro Yuseong-gu, Daejeon 34056, Korea
Choi JH: New and Renewable Energy Laboratory, KEPCO Research Institute, Korea Electric Power Corporation, 105 Munji-ro Yuseong-gu, Daejeon 34056, Korea [ORCID]
Lee SE: New and Renewable Energy Laboratory, KEPCO Research Institute, Korea Electric Power Corporation, 105 Munji-ro Yuseong-gu, Daejeon 34056, Korea
Park KY: New and Renewable Energy Laboratory, KEPCO Research Institute, Korea Electric Power Corporation, 105 Munji-ro Yuseong-gu, Daejeon 34056, Korea
Kim HS: New and Renewable Energy Laboratory, KEPCO Research Institute, Korea Electric Power Corporation, 105 Munji-ro Yuseong-gu, Daejeon 34056, Korea
Choi JH: New and Renewable Energy Laboratory, KEPCO Research Institute, Korea Electric Power Corporation, 105 Munji-ro Yuseong-gu, Daejeon 34056, Korea [ORCID]
Journal Name
Energies
Volume
14
Issue
17
First Page
5422
Year
2021
Publication Date
2021-08-31
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en14175422, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.19845v1
This Record
External Link

https://doi.org/10.3390/en14175422
Publisher Version
Download
Meta
Record Statistics
Record Views
297
Version History
[v1] (Original Submission)
Mar 9, 2023
Verified by curator on
Mar 9, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.19845v1
Record Owner
Auto Uploader for LAPSE
Links to Related Works
(0.08 seconds)
[0.08 s]