LAPSE:2023.19680
Published Article

LAPSE:2023.19680
Transient Analysis of Multiphase Transmission Lines Located above Frequency-Dependent Soils
March 9, 2023
Abstract
This paper evaluates the influence of frequency-dependent soil conductivity and permittivity in the transient responses of single- and double-circuit transmission lines including the ground wires subjected to lightning strikes. We use Nakagawa’s approach to compute the ground-return impedance and admittance matrices where the frequency-dependent soil is modeled using Alípio and Visacro’s model. We compare some elements of these matrices with those calculated by Carson’s approach which assumes the frequency constant. Results show that a significant difference can be obtained in high resistive soils for these elements in impedance and admittance matrices. Then, we compute the transient responses for single- and double-circuit lines with ground wires located above soils of 500, 1000, 5000, and 10,000 Ω·m considering the frequency constant and frequency-dependent parameters generated for two lightning strikes (subsequent stroke and Gaussian pulse). We demonstrate that the inclusion of frequency dependence of soil results in an expressive reduction of approximately 26.15% and 42.75% in the generated voltage peaks in single- and double-circuit lines located above a high-resistive soil. These results show the impact of the frequency-dependent soils that must be considered for a precise transient analysis in power systems.
This paper evaluates the influence of frequency-dependent soil conductivity and permittivity in the transient responses of single- and double-circuit transmission lines including the ground wires subjected to lightning strikes. We use Nakagawa’s approach to compute the ground-return impedance and admittance matrices where the frequency-dependent soil is modeled using Alípio and Visacro’s model. We compare some elements of these matrices with those calculated by Carson’s approach which assumes the frequency constant. Results show that a significant difference can be obtained in high resistive soils for these elements in impedance and admittance matrices. Then, we compute the transient responses for single- and double-circuit lines with ground wires located above soils of 500, 1000, 5000, and 10,000 Ω·m considering the frequency constant and frequency-dependent parameters generated for two lightning strikes (subsequent stroke and Gaussian pulse). We demonstrate that the inclusion of frequency dependence of soil results in an expressive reduction of approximately 26.15% and 42.75% in the generated voltage peaks in single- and double-circuit lines located above a high-resistive soil. These results show the impact of the frequency-dependent soils that must be considered for a precise transient analysis in power systems.
Record ID
Keywords
electromagnetic transient analysis, ground-return admittance, ground-return impedance, lightning, transmission lines
Subject
Suggested Citation
Garbelim Pascoalato TF, Justo de Araújo AR, Caballero PT, Leon Colqui JS, Kurokawa S. Transient Analysis of Multiphase Transmission Lines Located above Frequency-Dependent Soils. (2023). LAPSE:2023.19680
Author Affiliations
Garbelim Pascoalato TF: Department of Electrical Engineering, São Paulo State University (UNESP), Ilha Solteira 15.385-000, Brazil [ORCID]
Justo de Araújo AR: School of Electrical and Computer Engineering, State University of Campinas (UNICAMP), Campinas 13.083-872, Brazil [ORCID]
Caballero PT: Department of Electrical Engineering, São Paulo State University (UNESP), Ilha Solteira 15.385-000, Brazil [ORCID]
Leon Colqui JS: Department of Electrical Engineering, São Paulo State University (UNESP), Ilha Solteira 15.385-000, Brazil [ORCID]
Kurokawa S: Department of Electrical Engineering, São Paulo State University (UNESP), Ilha Solteira 15.385-000, Brazil [ORCID]
Justo de Araújo AR: School of Electrical and Computer Engineering, State University of Campinas (UNICAMP), Campinas 13.083-872, Brazil [ORCID]
Caballero PT: Department of Electrical Engineering, São Paulo State University (UNESP), Ilha Solteira 15.385-000, Brazil [ORCID]
Leon Colqui JS: Department of Electrical Engineering, São Paulo State University (UNESP), Ilha Solteira 15.385-000, Brazil [ORCID]
Kurokawa S: Department of Electrical Engineering, São Paulo State University (UNESP), Ilha Solteira 15.385-000, Brazil [ORCID]
Journal Name
Energies
Volume
14
Issue
17
First Page
5252
Year
2021
Publication Date
2021-08-25
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en14175252, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.19680
This Record
External Link

https://doi.org/10.3390/en14175252
Publisher Version
Download
Meta
Record Statistics
Record Views
306
Version History
[v1] (Original Submission)
Mar 9, 2023
Verified by curator on
Mar 9, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.19680
Record Owner
Auto Uploader for LAPSE
Links to Related Works
(0.07 seconds)
[0.08 s]
