Utilization of Thermally Activated Building System with Horizontal Ground Heat Exchanger Considering the Weather Conditions
March 6, 2023
Abstract
The thermally activated building system (TABS) can reduce the peak load by integrating with the ground heat exchangers. When integrated, the cost of groundwork and stability of the ground temperature would counteract because the weather conditions would influence the ground temperature in shallow depth. However, previous studies on TABS assumed constant ground temperatures such as average outdoor air temperature. In this study, ground temperatures in different depths are simulated for their detailed investigations, and simulated results of ground temperature were applied to building energy simulations for observing the load-handled ratio (LHR), representing the peak load reduction by TABS evaluated in various weather conditions. Simulation results of ground temperatures from 1 m to 39 m depths show that the temperature stabilized at 2 m to 11 m depths depending on the characteristics of the outdoor air temperature. LHR increased as the ground depth increased because the ground temperature at shallow depths increased during peak hours. Ground depths of 8 m were found ideal for maintaining consistent LHR for all weather conditions. Detailed observation of ground temperature and its effect on LHR in various weather conditions can help system engineers design and operate the TABS with the ground system.
The thermally activated building system (TABS) can reduce the peak load by integrating with the ground heat exchangers. When integrated, the cost of groundwork and stability of the ground temperature would counteract because the weather conditions would influence the ground temperature in shallow depth. However, previous studies on TABS assumed constant ground temperatures such as average outdoor air temperature. In this study, ground temperatures in different depths are simulated for their detailed investigations, and simulated results of ground temperature were applied to building energy simulations for observing the load-handled ratio (LHR), representing the peak load reduction by TABS evaluated in various weather conditions. Simulation results of ground temperatures from 1 m to 39 m depths show that the temperature stabilized at 2 m to 11 m depths depending on the characteristics of the outdoor air temperature. LHR increased as the ground depth increased because the ground temperature at shallow depths increased during peak hours. Ground depths of 8 m were found ideal for maintaining consistent LHR for all weather conditions. Detailed observation of ground temperature and its effect on LHR in various weather conditions can help system engineers design and operate the TABS with the ground system.
Record ID
Keywords
EnergyPlus, ground heat exchanger, KIVA, load-handled ratio, thermally activated building system
Subject
Suggested Citation
Chung WJ, Park SH. Utilization of Thermally Activated Building System with Horizontal Ground Heat Exchanger Considering the Weather Conditions. (2023). LAPSE:2023.17227
Author Affiliations
Journal Name
Energies
Volume
14
Issue
23
First Page
7927
Year
2021
Publication Date
2021-11-26
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en14237927, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.17227
This Record
External Link

https://doi.org/10.3390/en14237927
Publisher Version
Download
Meta
Record Statistics
Record Views
141
Version History
[v1] (Original Submission)
Mar 6, 2023
Verified by curator on
Mar 6, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.17227
Record Owner
Auto Uploader for LAPSE
Links to Related Works