Abstract
Power cycles on offshore oil and gas installations are expected to operate more at varied load conditions, especially when rapid growth in renewable energies puts them in a load-following operation. Part-load efficiency enhancement is advantageous since heat to power cycles suffer poor efficiency at part loads. The overall purpose of this article is to improve part-load efficiency in offshore combined cycles. Here, the organic Rankine bottoming cycle with a control strategy based on variable geometry turbine technology is studied to boost part-load efficiency. The Variable Area Nozzle turbine is selected to control cycle mass flow rate and pressure ratio independently. The design and performance of the proposed working strategy are assessed by an in-house developed tool. With the suggested solution, the part-load organic Rankine cycle efficiency is kept close to design value outperforming the other control strategies with sliding pressure, partial admission turbine, and throttling valve control operation. The combined cycle efficiency showed a clear improvement compared to the other strategies, resulting in 2.5 kilotons of annual carbon dioxide emission reduction per gas turbine unit. Compactness, autonomous operation, and acceptable technology readiness level for variable area nozzle turbines facilitate their application in offshore oil and gas installations.
Power cycles on offshore oil and gas installations are expected to operate more at varied load conditions, especially when rapid growth in renewable energies puts them in a load-following operation. Part-load efficiency enhancement is advantageous since heat to power cycles suffer poor efficiency at part loads. The overall purpose of this article is to improve part-load efficiency in offshore combined cycles. Here, the organic Rankine bottoming cycle with a control strategy based on variable geometry turbine technology is studied to boost part-load efficiency. The Variable Area Nozzle turbine is selected to control cycle mass flow rate and pressure ratio independently. The design and performance of the proposed working strategy are assessed by an in-house developed tool. With the suggested solution, the part-load organic Rankine cycle efficiency is kept close to design value outperforming the other control strategies with sliding pressure, partial admission turbine, and throttling valve control operation. The combined cycle efficiency showed a clear improvement compared to the other strategies, resulting in 2.5 kilotons of annual carbon dioxide emission reduction per gas turbine unit. Compactness, autonomous operation, and acceptable technology readiness level for variable area nozzle turbines facilitate their application in offshore oil and gas installations.
Record ID
Keywords
CO2 emission reduction, control strategy, off-design operation, offshore heat, process modelling and simulation, thermal efficiency
Subject
Suggested Citation
Motamed MA, Nord LO. Assessment of Organic Rankine Cycle Part-Load Performance as Gas Turbine Bottoming Cycle with Variable Area Nozzle Turbine Technology. (2023). LAPSE:2023.17221
Author Affiliations
Journal Name
Energies
Volume
14
Issue
23
First Page
7916
Year
2021
Publication Date
2021-11-26
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en14237916, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.17221
This Record
External Link

https://doi.org/10.3390/en14237916
Publisher Version
Download
Meta
Record Statistics
Record Views
142
Version History
[v1] (Original Submission)
Mar 6, 2023
Verified by curator on
Mar 6, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.17221
Record Owner
Auto Uploader for LAPSE
Links to Related Works