LAPSE:2023.1536
Published Article
LAPSE:2023.1536
Biocompatibility Study of a Cu-Al-Ni Rod Obtained by Continuous Casting
Marko Lazić, Minja Miličić Lazić, Milica Jakšić Karišik, Miloš Lazarević, Andraž Jug, Ivan Anžel, Jelena Milašin
February 21, 2023
Abstract
Cu-Al-Nishape memory alloys (SMAs) are widely known for their better properties in comparison to other SMAs (lower production costs, increased ductility, enhanced machinability, reduced liquidus temperature, and decreased hysteresis), but there is still controversy in terms of the biological properties of these materials. The aim of this study was to evaluate biofunctional performances of Cu-Al-Ni alloy produced by continuous casting. The micro-chemical analysis was investigated by SEM/EDX. Immersion tests performed for seven days were used to estimate the quantity of Cu, Al, and Ni ions released in neutral pH and slightly acidic artificial saliva. To assess the biocompatibility of the Cu-Al-Ni alloy samples, MTT assay on fibroblasts and dental pulp cells was performed in indirect and direct contact with samples after 1,3, and 7 days.The study revealed that continuous casting enables the primary fabrication of Cu-Al-Ni rods with a shape memory effect. Samples immersed in artificial saliva with 6.5 pH value showed no significant amounts of released ions, despite the high concentration of copper in the alloy. However, in the acidic environment, the suppression of Cu was 0.14 µg/cm2, Al 1.9 µg/cm2, and Ni 0.73 µg/cm2, and as expected, it was confirmed that Cu-Al-Ni alloy is not corrosion resistant in an acidic environment. In conclusion, this study showed that biocompatibility concerns are related only to materials with a high Cu content in acidic environments. Oppositely, small doses of Cu ions promote cell proliferation, which might be useful in further attempts to enrich different biomedical materials with copper.
Keywords
biocompatibility, cell proliferation, characterisation, Cu ions, Cu-Al-Ni rod, microstructure
Subject
Suggested Citation
Lazić M, Lazić MM, Karišik MJ, Lazarević M, Jug A, Anžel I, Milašin J. Biocompatibility Study of a Cu-Al-Ni Rod Obtained by Continuous Casting. (2023). LAPSE:2023.1536
Author Affiliations
Lazić M: School of Dental Medicine, University of Belgrade, 11000 Belgrade, Serbia
Lazić MM: School of Dental Medicine, University of Belgrade, 11000 Belgrade, Serbia
Karišik MJ: School of Dental Medicine, University of Belgrade, 11000 Belgrade, Serbia
Lazarević M: School of Dental Medicine, University of Belgrade, 11000 Belgrade, Serbia [ORCID]
Jug A: Faculty of Mechanical Engineering, University of Maribor, 2000 Maribor, Slovenia
Anžel I: Faculty of Mechanical Engineering, University of Maribor, 2000 Maribor, Slovenia
Milašin J: School of Dental Medicine, University of Belgrade, 11000 Belgrade, Serbia [ORCID]
Journal Name
Processes
Volume
10
Issue
8
First Page
1507
Year
2022
Publication Date
2022-07-29
ISSN
2227-9717
Version Comments
Original Submission
Other Meta
PII: pr10081507, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.1536
This Record
External Link

https://doi.org/10.3390/pr10081507
Publisher Version
Download
Files
Feb 21, 2023
Main Article
License
CC BY 4.0
Meta
Record Statistics
Record Views
368
Version History
[v1] (Original Submission)
Feb 21, 2023
 
Verified by curator on
Feb 21, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.1536
 
Record Owner
Auto Uploader for LAPSE
Links to Related Works
Directly Related to This Work
Publisher Version

[0.22 s]