Smart grid technology has received ample attention in past years to develop the traditional power distribution network and to enable the integration of distributed generation units (DGs) to satisfy increasing demand loads and to improve network performance. In addition to DGs, integration of shunt capacitors (SCs) along with network reconfiguration can also play an important role in improving network performance. Besides, network reconfiguration can help to increase the distributed generation hosting capacity of the network. Some of the research in the literature have presented and discussed the problem of optimal integration of renewable DGs and SCs along with optimal network reconfiguration, while the network load variability and/or the intermittent nature of renewable DGs are neglected. For the work presented in this paper, the SHADE optimization algorithm along with the SOE reconfiguration method have been employed for solving the aforementioned optimization problem with consideration of uncertainty related to both the network load and the output power of the renewable DGs. Maximizing the hosting capacity (HC) of the DGs and reducing network power losses in addition to improving the voltage profile have been considered as optimization objectives. Five different case studies have been conducted considering 33-bus and 59-bus distribution networks. The obtained results validate the effectiveness and the superiority of the employed techniques for maximizing the HC up to 17% and reducing power losses up to 95%. Besides, the results also depict the effect of SC integration and the consideration of uncertainties on achieving the optimization objectives with realistic modeling of the optimization problem.
Smart grid technology has received ample attention in past years to develop the traditional power distribution network and to enable the integration of distributed generation units (DGs) to satisfy increasing demand loads and to improve network performance. In addition to DGs, integration of shunt capacitors (SCs) along with network reconfiguration can also play an important role in improving network performance. Besides, network reconfiguration can help to increase the distributed generation hosting capacity of the network. Some of the research in the literature have presented and discussed the problem of optimal integration of renewable DGs and SCs along with optimal network reconfiguration, while the network load variability and/or the intermittent nature of renewable DGs are neglected. For the work presented in this paper, the SHADE optimization algorithm along with the SOE reconfiguration method have been employed for solving the aforementioned optimization problem with consideration of uncertainty related to both the network load and the output power of the renewable DGs. Maximizing the hosting capacity (HC) of the DGs and reducing network power losses in addition to improving the voltage profile have been considered as optimization objectives. Five different case studies have been conducted considering 33-bus and 59-bus distribution networks. The obtained results validate the effectiveness and the superiority of the employed techniques for maximizing the HC up to 17% and reducing power losses up to 95%. Besides, the results also depict the effect of SC integration and the consideration of uncertainties on achieving the optimization objectives with realistic modeling of the optimization problem.
Record ID
Keywords
distributed generators, network reconfiguration, power loss minimization, renewable energy sources, SHADE, shunt capacitors, switch opening and exchange method, uncertainty
Subject
Suggested Citation
Sayed MM, Mahdy MY, Abdel Aleem SHE, Youssef HKM, Boghdady TA. Simultaneous Distribution Network Reconfiguration and Optimal Allocation of Renewable-Based Distributed Generators and Shunt Capacitors under Uncertain Conditions. (2023). LAPSE:2023.14845v1
Author Affiliations
Sayed MM: Electrical Power and Machines Department, Faculty of Engineering, Cairo University, Cairo 12613, Egypt
Mahdy MY: Electrical Power and Machines Department, Faculty of Engineering, Cairo University, Cairo 12613, Egypt
Abdel Aleem SHE: Department of Electrical Engineering, Valley High Institute of Engineering and Technology, Science Valley Academy, Qalubia 44971, Egypt [ORCID]
Youssef HKM: Electrical Power and Machines Department, Faculty of Engineering, Cairo University, Cairo 12613, Egypt
Boghdady TA: Electrical Power and Machines Department, Faculty of Engineering, Cairo University, Cairo 12613, Egypt [ORCID]
Mahdy MY: Electrical Power and Machines Department, Faculty of Engineering, Cairo University, Cairo 12613, Egypt
Abdel Aleem SHE: Department of Electrical Engineering, Valley High Institute of Engineering and Technology, Science Valley Academy, Qalubia 44971, Egypt [ORCID]
Youssef HKM: Electrical Power and Machines Department, Faculty of Engineering, Cairo University, Cairo 12613, Egypt
Boghdady TA: Electrical Power and Machines Department, Faculty of Engineering, Cairo University, Cairo 12613, Egypt [ORCID]
Journal Name
Energies
Volume
15
Issue
6
First Page
2299
Year
2022
Publication Date
2022-03-21
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en15062299, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.14845v1
This Record
External Link

https://doi.org/10.3390/en15062299
Publisher Version
Download
Meta
Record Statistics
Record Views
394
Version History
[v1] (Original Submission)
Mar 1, 2023
Verified by curator on
Mar 1, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.14845v1
Record Owner
Auto Uploader for LAPSE
Links to Related Works
(0.09 seconds)
[0.09 s]