Comparison of Ground-Based Global Horizontal Irradiance and Direct Normal Irradiance with Satellite-Based SUNY Model
Adnan Ayaz, Faraz Ahmad, Mohammad Abdul Aziz Irfan, Zabdur Rehman, Krzysztof Rajski, Jan Danielewicz
March 1, 2023
Abstract
Since the fossil reserves are depleting day by day, the trend of modern energy sector is going towards renewable energy. The demand of solar power plants is therefore at the peak nowadays across the globe. However, the construction of these plants is extremely dependent on feasibility study to estimate the real solar potential before installing it in any region. To evaluate the solar energy potential of Peshawar region in Pakistan, Ground-based global horizontal irradiance (GHI) and direct normal irradiance (DNI) were compared with satellite-based model SUNY. Ground measurements were done at the University of Engineering and Technology Peshawar (UET Peshawar) with the help of pyranometer and shadowband irradiometer. Comparison of the data showed that there was a maximum difference of 42.90% in ground and satellite-based GHI in the month of December. Minimum difference in GHI was found for the month of March that was −3.83%. Moreover, ground-based GHI was overestimated in the month of February, March, and April, while in rest of the months, satellite values of GHI exceeded the ground measurements. Similarly, maximum difference of 55.86% was found in the month of November between ground and satellite-based DNI while minimum difference of −3.34% was seen in DNI in the month of March between the two data. Furthermore, satellite-based DNI was underestimated in the months of February, March, and April while in rest of the months it was overestimated compared to ground measurements. In addition to this, correlation of ground and satellite-based GHI and DNI showed R2 value of 0.8852 and 0.4139, respectively. The results of this study revealed that the difference between ground measurements and satellite values was considerable and hence real time measurements are necessary to properly estimate solar energy resource in the country.
Keywords
combined uncertainty, direct normal irradiance, global horizontal irradiance, satellite based SUNY model
Suggested Citation
Ayaz A, Ahmad F, Irfan MAA, Rehman Z, Rajski K, Danielewicz J. Comparison of Ground-Based Global Horizontal Irradiance and Direct Normal Irradiance with Satellite-Based SUNY Model. (2023). LAPSE:2023.14283
Author Affiliations
Ayaz A: Mechanical Engineering Department, University of Engineering and Technology Peshawar, Peshawar 25120, Pakistan
Ahmad F: Department of Mechanical Engineering, Aerospace and Aviation Campus Kamra, Air University Islamabad, Kamra 43570, Pakistan [ORCID]
Irfan MAA: Mechanical Engineering Department, University of Engineering and Technology Peshawar, Peshawar 25120, Pakistan [ORCID]
Rehman Z: Department of Mechanical Engineering, Aerospace and Aviation Campus Kamra, Air University Islamabad, Kamra 43570, Pakistan
Rajski K: Faculty of Environmental Engineering, Wrocław University of Science and Technology, PL50377 Wrocław, Poland [ORCID]
Danielewicz J: Faculty of Environmental Engineering, Wrocław University of Science and Technology, PL50377 Wrocław, Poland
Journal Name
Energies
Volume
15
Issue
7
First Page
2528
Year
2022
Publication Date
2022-03-30
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en15072528, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.14283
This Record
External Link

https://doi.org/10.3390/en15072528
Publisher Version
Download
Files
Mar 1, 2023
Main Article
License
CC BY 4.0
Meta
Record Statistics
Record Views
307
Version History
[v1] (Original Submission)
Mar 1, 2023
 
Verified by curator on
Mar 1, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.14283
 
Record Owner
Auto Uploader for LAPSE
Links to Related Works
Directly Related to This Work
Publisher Version
(0.07 seconds)

[0.07 s]