LAPSE:2023.13540
Published Article

LAPSE:2023.13540
High Efficiency Transformerless Photovoltaic DC/AC Converter with Common Mode Leakage Current Elimination: Analysis and Implementation
March 1, 2023
Abstract
Photovoltaic (PV) electricity is widely used because of its positive environmental impact. To properly feed this energy into the grid, an electronic power converter, known as a PV inverter, is needed, which may or may not use a transformer. This article details the analysis and design of a transformerless photovoltaic inverter topology for grid-connected applications. This converter offers high efficiency, a low number of elements, and negligible leakage current, which makes it a good alternative for this application. The converter has been validated through an experimental prototype and compared with other topologies with similar characteristics.
Photovoltaic (PV) electricity is widely used because of its positive environmental impact. To properly feed this energy into the grid, an electronic power converter, known as a PV inverter, is needed, which may or may not use a transformer. This article details the analysis and design of a transformerless photovoltaic inverter topology for grid-connected applications. This converter offers high efficiency, a low number of elements, and negligible leakage current, which makes it a good alternative for this application. The converter has been validated through an experimental prototype and compared with other topologies with similar characteristics.
Record ID
Keywords
common-mode (CM), leakage current, photovoltaic systems, transformerless inverter
Subject
Suggested Citation
Cardoso J, Orosco R, Vazquez N, López H, Hernandez C, Vaquero J. High Efficiency Transformerless Photovoltaic DC/AC Converter with Common Mode Leakage Current Elimination: Analysis and Implementation. (2023). LAPSE:2023.13540
Author Affiliations
Cardoso J: Tecnológico Nacional de México/Instituto Tecnológico de Celaya, Celaya 38010, Mexico
Orosco R: Tecnológico Nacional de México/Instituto Tecnológico de Celaya, Celaya 38010, Mexico
Vazquez N: Tecnológico Nacional de México/Instituto Tecnológico de Celaya, Celaya 38010, Mexico [ORCID]
López H: Tecnológico Nacional de México/Instituto Tecnológico de Celaya, Celaya 38010, Mexico
Hernandez C: Tecnológico Nacional de México/Instituto Tecnológico de Celaya, Celaya 38010, Mexico
Vaquero J: Área de Tecnología Electrónica, Universidad Rey Juan Carlos, 28933 Madrid, Spain [ORCID]
Orosco R: Tecnológico Nacional de México/Instituto Tecnológico de Celaya, Celaya 38010, Mexico
Vazquez N: Tecnológico Nacional de México/Instituto Tecnológico de Celaya, Celaya 38010, Mexico [ORCID]
López H: Tecnológico Nacional de México/Instituto Tecnológico de Celaya, Celaya 38010, Mexico
Hernandez C: Tecnológico Nacional de México/Instituto Tecnológico de Celaya, Celaya 38010, Mexico
Vaquero J: Área de Tecnología Electrónica, Universidad Rey Juan Carlos, 28933 Madrid, Spain [ORCID]
Journal Name
Energies
Volume
15
Issue
9
First Page
3177
Year
2022
Publication Date
2022-04-27
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en15093177, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.13540
This Record
External Link

https://doi.org/10.3390/en15093177
Publisher Version
Download
Meta
Record Statistics
Record Views
159
Version History
[v1] (Original Submission)
Mar 1, 2023
Verified by curator on
Mar 1, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.13540
Record Owner
Auto Uploader for LAPSE
Links to Related Works