LAPSE:2024.0699
Published Article
LAPSE:2024.0699
Research on Radial Double Velocity Measurement Method of Laser Tracker
Fei Lv, Chang’an Hu, Jiangang Li, Yue Xu
June 6, 2024
Abstract
For the dynamic problem that the low-speed sliding table is unable to meet the radial measuring speed of the laser tracker, this paper takes the sliding table of the indoor large-length standard device as the moving object to double the measuring distance by adding a pyramid prism, thereby doubling the radial speed of the laser tracker. In this paper, the measurement data are analyzed through equal interval measurement experiments, equal sampling frequency experiments and repeatability measurement experiments using a pyramid prism to obtain the following conclusions, respectively: Firstly, the stability of the actual interval of the laser tracker is optimal when the rated speed of the sliding table is 50 mm/s. When the pyramid prism is not used, the minimum standard deviation obtained by the laser tracker at a sampling interval of 5 mm is 0.0158 mm. Secondly, during the equal sampling frequency measurement, the stability of the laser interferometer is better than that of the laser tracker when the pyramid prism is not used. With two instruments at a sampling frequency of 10 Hz, the standard deviations of the local velocity of the laser interferometer are 0.1466 mm/s, 0.0693 mm/s and 0.1106 mm/s, respectively. The standard deviations of the laser tracker are 0.1582 mm/s, 0.1033 mm/s and 0.2008 mm/s, respectively. The same conclusion is obtained at a sampling frequency of 20 Hz. The stability of the laser tracker is better than that of the laser interferometer when the pyramid prism is used. Thirdly, the stability and reliability of the local velocity of the laser tracker are better than that of the laser interferometer. For example, at 10 Hz, the standard deviations of the local velocity of the laser tracker are 0.2745 mm/s and 0.2097 mm/s, respectively, and the repeatability of the local velocity is 0.9140 mm/s. The standard deviations of the local velocity of the interferometer are 0.6141 mm/s and 0.6368 mm/s, respectively, and the repeatability of the local velocity is 1.4886 mm/s. And the local velocity of the two measuring instruments is more reliable and stable at a low frequency (10 Hz). This experimental scheme provides a way to measure the high speed of a laser tracker using a sliding table at low speed.
Keywords
equal measurement interval, equal sampling frequency, indoor large-length standard device, laser interferometer, laser tracker, pyramid prism, radial measuring speed, repeatability measurement
Suggested Citation
Lv F, Hu C, Li J, Xu Y. Research on Radial Double Velocity Measurement Method of Laser Tracker. (2024). LAPSE:2024.0699
Author Affiliations
Lv F: School of Computer Science, Chengdu Normal University, Chengdu 611130, China
Hu C: National Institute of Measurement and Testing Technology, Chengdu 610021, China [ORCID]
Li J: National Institute of Measurement and Testing Technology, Chengdu 610021, China
Xu Y: School of Automation, Northwestern Polytechnical University, Xi’an 710129, China
Journal Name
Processes
Volume
12
Issue
4
First Page
649
Year
2024
Publication Date
2024-03-24
ISSN
2227-9717
Version Comments
Original Submission
Other Meta
PII: pr12040649, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2024.0699
This Record
External Link

https://doi.org/10.3390/pr12040649
Publisher Version
Download
Files
Jun 6, 2024
Main Article
License
CC BY 4.0
Meta
Record Statistics
Record Views
984
Version History
[v1] (Original Submission)
Jun 6, 2024
 
Verified by curator on
Jun 6, 2024
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2024.0699
 
Record Owner
Auto Uploader for LAPSE
Links to Related Works
Directly Related to This Work
Publisher Version
(0.16 seconds)

[0.17 s]