In the last few decades, an average method which is regulated by ISO 9869-1 has been used to evaluate the in situ thermal transmittance (U-value) and thermal resistance (R-value) of building envelopes obtained from onsite measurements and to verify the validity of newly proposed methods. Nevertheless, only a few studies have investigated the test duration required to obtain reliable results using this method and the convergence characteristics of the results. This study aims to evaluate the convergence characteristics of the in situ values analyzed using the average method. The criteria for determining convergence (i.e., end of the test) using the average method are very strict, mainly because of the third condition, which compares the deviation of two values derived from the first and last periods of the same duration. To shorten the test duration, environmental variables should be kept constant throughout the test or an appropriate period should be selected. The convergence of the in situ U-value and R-value is affected more by the length of the test duration than by the temperature difference if the test environment meets literature-recommended conditions. Furthermore, there is no difference between the use of the U-value and R-value in determining the end of the test.
In the last few decades, an average method which is regulated by ISO 9869-1 has been used to evaluate the in situ thermal transmittance (U-value) and thermal resistance (R-value) of building envelopes obtained from onsite measurements and to verify the validity of newly proposed methods. Nevertheless, only a few studies have investigated the test duration required to obtain reliable results using this method and the convergence characteristics of the results. This study aims to evaluate the convergence characteristics of the in situ values analyzed using the average method. The criteria for determining convergence (i.e., end of the test) using the average method are very strict, mainly because of the third condition, which compares the deviation of two values derived from the first and last periods of the same duration. To shorten the test duration, environmental variables should be kept constant throughout the test or an appropriate period should be selected. The convergence of the in situ U-value and R-value is affected more by the length of the test duration than by the temperature difference if the test environment meets literature-recommended conditions. Furthermore, there is no difference between the use of the U-value and R-value in determining the end of the test.
Record ID
Keywords
average method, convergence characteristics, heat flow meter method, opaque exterior wall, thermal resistance, thermal transmittance
Subject
Suggested Citation
Choi DS, Ko MJ. Analysis of Convergence Characteristics of Average Method Regulated by ISO 9869-1 for Evaluating In Situ Thermal Resistance and Thermal Transmittance of Opaque Exterior Walls. (2023). LAPSE:2023.4120
Author Affiliations
Journal Name
Energies
Volume
12
Issue
10
Article Number
E1989
Year
2019
Publication Date
2019-05-24
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en12101989, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.4120
This Record
External Link

https://doi.org/10.3390/en12101989
Publisher Version
Download
Meta
Record Statistics
Record Views
442
Version History
[v1] (Original Submission)
Feb 22, 2023
Verified by curator on
Feb 22, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.4120
Record Owner
Auto Uploader for LAPSE
Links to Related Works
(0.07 seconds)
[0.07 s]