LAPSE:2023.36406
Published Article

LAPSE:2023.36406
The Investigation of Two-Phase Expansion Performance with Indicator Diagram in a Twin-Screw Expander
July 13, 2023
Abstract
Volumetric expanders are proven to be more suitable for small-scale waste heat recovery applications because of their simplicity, reliability, lower rotational speed and lower cost. Unlike turbines, volumetric expanders can work in the two-phase fluid state, which broadens their application fields. To investigate the two-phase performance of volumetric expanders, a specific twin-screw expander was chosen and modeled. The leakage loss and the suction pressure loss were primary concerns in this research. The two-phase expansion process in the expander is presented in detail using the developed mathematical model with an indicator diagram. The influence of several factors, including inlet vapor quality, rotational speed and intake pressure, are investigated. The influence mechanism of the vapor phase and the liquid phase on expander performance is clarified. In brief, this paper presents an illustrative understanding of the two-phase expansion process in twin-screw expanders.
Volumetric expanders are proven to be more suitable for small-scale waste heat recovery applications because of their simplicity, reliability, lower rotational speed and lower cost. Unlike turbines, volumetric expanders can work in the two-phase fluid state, which broadens their application fields. To investigate the two-phase performance of volumetric expanders, a specific twin-screw expander was chosen and modeled. The leakage loss and the suction pressure loss were primary concerns in this research. The two-phase expansion process in the expander is presented in detail using the developed mathematical model with an indicator diagram. The influence of several factors, including inlet vapor quality, rotational speed and intake pressure, are investigated. The influence mechanism of the vapor phase and the liquid phase on expander performance is clarified. In brief, this paper presents an illustrative understanding of the two-phase expansion process in twin-screw expanders.
Record ID
Keywords
low grade heat, twin-screw expander, two-phase expansion, waste heat recovery
Subject
Suggested Citation
Ma Y, Zhou Y, Zhu Z. The Investigation of Two-Phase Expansion Performance with Indicator Diagram in a Twin-Screw Expander. (2023). LAPSE:2023.36406
Author Affiliations
Ma Y: Department of Thermal Engineering, Shandong Jianzhu University, Jinan 250101, China [ORCID]
Zhou Y: Shanghai Marine Diesel Engine Research Institute, Shanghai 201108, China
Zhu Z: Shandong Xianghuan Environmental Technology Co., Ltd., Jinan 250001, China
Zhou Y: Shanghai Marine Diesel Engine Research Institute, Shanghai 201108, China
Zhu Z: Shandong Xianghuan Environmental Technology Co., Ltd., Jinan 250001, China
Journal Name
Processes
Volume
11
Issue
6
First Page
1862
Year
2023
Publication Date
2023-06-20
ISSN
2227-9717
Version Comments
Original Submission
Other Meta
PII: pr11061862, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.36406
This Record
External Link

https://doi.org/10.3390/pr11061862
Publisher Version
Download
Meta
Record Statistics
Record Views
253
Version History
[v1] (Original Submission)
Jul 13, 2023
Verified by curator on
Jul 13, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.36406
Record Owner
Calvin Tsay
Links to Related Works