LAPSE:2023.32049
Published Article
LAPSE:2023.32049
Concepts and Methods to Assess the Dynamic Thermal Rating of Underground Power Cables
April 19, 2023
Abstract
With the increase in the electrical load and the progressive introduction of power generation from intermittent renewable energy sources, the power line operating conditions are approaching the thermal limits. The definition of thermal limits variable in time has been addressed under the concept of dynamic thermal rating (DTR), with which it is possible to provide a more detailed assessment of the line rating and exploit the electrical system more flexibly. Most of the literature on DTR has addressed overhead lines exposed to different weather conditions. The interest in the dynamic thermal rating of power cables is increasing, considering the evolution of computational methods and advanced systems for cable monitoring. This paper contains an overview of the concepts and methods referring to dynamic cable rating (DCR). Starting from the analytical formulations developed many years ago for determining the power cable rating in steady-state conditions, also reported in International Standards, this paper considers the improvements of these formulations proposed during the years. These improvements are leading to include more specific details in the models used for DCR analysis and the computational methods used to assess the power cable’s thermal conditions buried in soil. This paper is focused on highlighting the path from the initial theories and models to the latest literature contributions. Attention is paid to thermal modelling with different levels of detail, applications of 2D and 3D solvers and simplified models, and their validation based on experimental measurements. A salient point of the overview is considering the DCR impact on reliability aspects, risk estimation, real-time calculations, forecasting, and planning with different time horizons.
Keywords
cable rating, dynamic line rating, electric cable, monitoring, reliability, review, thermal model
Suggested Citation
Enescu D, Colella P, Russo A, Porumb RF, Seritan GC. Concepts and Methods to Assess the Dynamic Thermal Rating of Underground Power Cables. (2023). LAPSE:2023.32049
Author Affiliations
Enescu D: Electronics Telecommunications and Energy Department, University Valahia of Targoviste, 130004 Targoviște, Romania [ORCID]
Colella P: Dipartimento Energia “Galileo Ferraris”, Politecnico di Torino, 10129 Torino, Italy [ORCID]
Russo A: Dipartimento Energia “Galileo Ferraris”, Politecnico di Torino, 10129 Torino, Italy [ORCID]
Porumb RF: Electrical Power Systems Department, University Politehnica of Bucharest, RO-060042 Bucharest, Romania
Seritan GC: Department of Measurements, Electrical Devices and Static Converters, University Politehnica of Bucharest, RO-060042 Bucharest, Romania [ORCID]
Journal Name
Energies
Volume
14
Issue
9
First Page
2591
Year
2021
Publication Date
2021-05-01
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en14092591, Publication Type: Review
Record Map
Published Article

LAPSE:2023.32049
This Record
External Link

https://doi.org/10.3390/en14092591
Publisher Version
Download
Files
Apr 19, 2023
Main Article
License
CC BY 4.0
Meta
Record Statistics
Record Views
529
Version History
[v1] (Original Submission)
Apr 19, 2023
 
Verified by curator on
Apr 19, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.32049
 
Record Owner
Auto Uploader for LAPSE
Links to Related Works
Directly Related to This Work
Publisher Version
(0.1 seconds)

[0.1 s]