Pump intake structure design is one area where physical models still remain as the only acceptable method that can provide reliable engineering results. Ensuring the amount of turbulence, entrained air vortices, and swirl are kept within acceptable limits requires site-specific, expensive, and time-consuming physical model studies. This study aims to investigate the viability of Computational Fluid Dynamics (CFD) as an alternative tool for pump intake design thus reducing the need for extensive physical experiments. In this study, a transient multiphase simulation of a 530 mm wide rectangular intake sump housing a 116 m3/h pump is presented. The flow conditions, vortex formation and inlet swirl are compared to an existing 1:10 reduced scaled physical model test. For the baseline test, the predicted surface and submerged vortices agreed well with those observed in the physical model. Both the physical model test and the numerical model showed that the initial geometry of the pump sump is unacceptable as per ANSI/HI 9.8 criteria. Strong type 2 to type 3 submerged vortices were observed at the floor of the pump and behind the pump. Consequently, numerical simulations of proposed sump design modification are further investigated. Two CFD models with different fillet-splitter designs are evaluated and compared based on the vortex formation and swirl. In the study, it was seen that a trident-shaped splitter design was able to prevent flow separation and vortex suppression as compared to a cross-baffle design based on ANSI/HI 9.8. CFD results for the cross-baffle design showed that backwall and floor vortices were still present and additional turbulence was observed due to the cross-flow caused by the geometry. Conversely, CFD results for the trident-shaped fillet-splitter design showed stable flow and minimized the floor and wall vortices previously observed in the first two models.
Keywords
Computational Fluid Dynamics, free surface flow, free surface vortices, intake structures, physical hydraulic model, vertical pump
Suggested Citation
Arocena VM, Abuan BE, Reyes JGT, Rodgers PL, Danao LAM. Reduction of Entrained Vortices in Submersible Pump Suction Lines Using Numerical Simulations. (2023). LAPSE:2023.27756
Author Affiliations
Arocena VM: Department of Mechanical Engineering, University of the Philippines, Diliman, Quezon City 1101, Philippines
Abuan BE: Department of Mechanical Engineering, University of the Philippines, Diliman, Quezon City 1101, Philippines
Reyes JGT: Department of Mechanical Engineering, University of the Philippines, Diliman, Quezon City 1101, Philippines
Rodgers PL: Department of Mechanical Engineering, University of the Philippines, Diliman, Quezon City 1101, Philippines
Danao LAM: Department of Mechanical Engineering, University of the Philippines, Diliman, Quezon City 1101, Philippines [ORCID]
Journal Name
Energies
Volume
13
Issue
22
Article Number
E6136
Year
2020
Publication Date
2020-11-23
Published Version
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en13226136, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.27756
This Record
External Link

doi:10.3390/en13226136
Publisher Version
Download
Files
[Download 1v1.pdf] (12.1 MB)
Apr 4, 2023
Main Article
License
CC BY 4.0
Meta
Record Statistics
Record Views
71
Version History
[v1] (Original Submission)
Apr 4, 2023
 
Verified by curator on
Apr 4, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.27756
 
Original Submitter
Auto Uploader for LAPSE
Links to Related Works
Directly Related to This Work
Publisher Version